EUVIMEDEUVIMED entdecken
Crossref

Comparison of Hill Radial Basis Activation Function-2, Barrett Universal II, and Ladas Super Formula Intraocular Lens Power Calculation Formulas

Ali Moradi, Aryan Ayati, Azin Pakmehr, Farsad Noorizadeh, Seyed Ali Mirshahvalad, Ahmad Shojaei, Soheila Sobhani, Fatemeh Vafaei

Journal of Ophthalmic and Optometric Sciences · 04.02.2025

DOI: 10.22037/joos.v7i4.47445 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Ophthalmic and Optometric Sciences, erschienen am 04.02.2025. Verfasst von Ali Moradi und 7 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to compare the predictability and accuracy of different formulas for calculating the power of Tecnis ZCB00 intraocular lenses (IOLs) in patients undergoing cataract surgery.Patients and Methods: A retrospective comparative analysis was conducted at Basir Eye Clinic, Tehran, Iran, involving 491 eyes of 491 patients who underwent cataract surgery with Tecnis ZCB00 IOL insertion. Biometry data were entered into calculators for SRK/T, Hill Radial Basis Activation Function-2 (Hill RBF- 2), Barrett Universal II, and Ladas Super Formula. Tecnis ZCB00 IOL was implanted for all patients with the power calculated by SRK/T formula. The mean refractive prediction error was compared between Hill RBF- 2, Barrett Universal II, and Ladas Super Formula.

Results

The mean refractive prediction error when considering the IOL power calculations using the Ladas Super Formula, Hill RBF-2, and Barrett Universal II were 1.07 ± 1.11, 0.97 ± 0.82, 1.21 ± 1.04, respectively (P < 0.01). Also, there was a significant difference between the formulas when accessing patients with short axial length (worst results with Barrett Universal II, P < 0.01), medium axial length (best results with Hill RBF-2, P < 0.01) and long axial length (worst results with Barrett Universal II, P < 0.01).

Conclusion

For TECNIS® ZCB00 IOLs, the calculation of IOL power yielded the highest mean refractive prediction error with the Barrett Universal II formula.

Schlagwörter

intraocular lens power calculationBarrett Universal IIcataract surgeryrefractive prediction erroraxial length

Zitieren

APA

Moradi, A., Ayati, A., Pakmehr, A., Noorizadeh, F., Mirshahvalad, S. A., Shojaei, A., Sobhani, S., & Vafaei, F. (2025). Comparison of Hill Radial Basis Activation Function-2, Barrett Universal II, and Ladas Super Formula Intraocular Lens Power Calculation Formulas. Journal of Ophthalmic and Optometric Sciences. https://doi.org/10.22037/joos.v7i4.47445

Vancouver

Moradi A, Ayati A, Pakmehr A, Noorizadeh F, Mirshahvalad SA, Shojaei A, et al. Comparison of Hill Radial Basis Activation Function-2, Barrett Universal II, and Ladas Super Formula Intraocular Lens Power Calculation Formulas. Journal of Ophthalmic and Optometric Sciences. 2025. doi:10.22037/joos.v7i4.47445

BibTeX
@article{Moradi2025,
  author = {Moradi, Ali and Ayati, Aryan and Pakmehr, Azin and Noorizadeh, Farsad and Mirshahvalad, Seyed Ali and Shojaei, Ahmad and Sobhani, Soheila and Vafaei, Fatemeh},
  title = {Comparison of Hill Radial Basis Activation Function-2, Barrett Universal II, and Ladas Super Formula Intraocular Lens Power Calculation Formulas},
  journal = {Journal of Ophthalmic and Optometric Sciences},
  year = {2025},
  doi = {10.22037/joos.v7i4.47445}
}
Kostenlos starten →