Comparing Refractive Prediction Accuracy of IOL Master 700 and Sirius Utilizing the Barrett Universal II Formula
Clinical Ophthalmology · 2026-01 · Volume 20 · 1-10
DOI: 10.2147/opth.s560886 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Ophthalmology, 2026-01. Verfasst von Junjie Yang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, People's Republic …. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Purpose
To compare the refractive-prediction error (the difference between the predicted post-operative spherical equivalent and the actual spherical equivalent) of IOLMaster 700 and Sirius when their biometric data are fed into the Barrett Universal II formula.
Setting
Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
Design
Prospective, observational, single-center, paired-eye study.
Methods
123 eyes of 93 cataract patients were enrolled. The participants ranged in age from 36 to 91 years, with a mean age of 65.38 ± 14.84 years. Axial length from IOLMaster 700 and corneal curvature, anterior-chamber depth and white-to-white from both devices were entered into the BarErett Universal II calculator to obtain predicted post-operative spherical equivalent (PRP). One week after uneventful phacoemulsification with monofocal intraocular lens implantation, manifest refraction provided the actual spherical equivalent (SE). Prediction error (ΔPRE = PRP - SE) and absolute error |ΔPRE| were primary outcomes.
Results
Both devices produced positive ΔPRE, but the median was lower for IOLMaster 700 than for Sirius (0.41 D vs 0.73 D; p 25 mm) and normal axial-length eyes.
Conclusion
Under the Barrett Universal II formula, IOLMaster 700 yields more accurate refractive predictions than Sirius, with smaller systematic drift and absolute error, irrespective of axial length. Thus, IOLMaster 700 with Barrett Universal II is the preferred biometry for superior refractive accuracy. This study offers surgeons practical guidance for improving post-operative visual outcomes and patient satisfaction.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, People's Republic of China.
ORCID-Profile: Yuying Xiang
Zitieren
APA
Yang, J., Yang, N., Xiang, Y., Li, R., Yu, X., Jin, L., & Huang, Y. (2026). Comparing Refractive Prediction Accuracy of IOL Master 700 and Sirius Utilizing the Barrett Universal II Formula. Clinical Ophthalmology, Volume 20, 1-10. https://doi.org/10.2147/opth.s560886
Vancouver
Yang J, Yang N, Xiang Y, Li R, Yu X, Jin L, et al. Comparing Refractive Prediction Accuracy of IOL Master 700 and Sirius Utilizing the Barrett Universal II Formula. Clinical Ophthalmology. 2026;Volume 20:1-10. doi:10.2147/opth.s560886
BibTeX
@article{Yang2026,
author = {Yang, Junjie and Yang, Nijuan and Xiang, Yuying and Li, Rui and Yu, Xuan and Jin, Ling and Huang, Yukan},
title = {Comparing Refractive Prediction Accuracy of IOL Master 700 and Sirius Utilizing the Barrett Universal II Formula},
journal = {Clinical Ophthalmology},
year = {2026},
volume = {Volume 20},
pages = {1--10},
doi = {10.2147/opth.s560886}
}
EUVIMED