Effect of off-axis osteotomy preparation and depth on intraosseous temperature during implant site preparation: an in vitro study
Journal of Medicine and Palliative Care · 25.06.2026 · 7 (3) · 562-568
DOI: 10.47582/jompac.1900158 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medicine and Palliative Care, online erschienen am 25.06.2026. Verfasst von Tolga Yılmaz und 1 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Gefördert von: The authors declared that this study has received no financial support..
Abstract (Originalsprache)
Aims
Thermal trauma during implant site preparation may adversely affect bone vitality and compromise osseointegration. Drilling parameters such as angulation and depth are considered important factors influencing heat generation in bone during implant surgery. The aim of this in vitro study was to evaluate the effect of different off-axis osteotomy angulations and depths on intraosseous temperature changes during implant site preparation.
Methods
This in vitro experimental study was conducted using fresh bovine femur cortical bone specimens. Implant osteotomies were performed at three different off-axis osteotomy angulations (0°, 17°, and 30°) and four measurement depths (0, 9, 11, and 13 mm). Temperature changes were recorded using K-type thermocouple sensors positioned 1 mm from the drilling site. Drilling was performed for a standardized duration under constant irrigation. The maximum temperature reached at each depth and angle was recorded and statistically analyzed.
Results
The mean intraosseous temperature increased from 35.69°C, 35.68°C, and 35.79°C at baseline to 41.45°C, 41.86°C, and 42.37°C at 13 mm for the 0°, 17°, and 30° groups, respectively. Temperature increased significantly with depth in all groups (p
Förderung
- The authors declared that this study has received no financial support.
Zitieren
APA
Yılmaz, T., & Yanık, S. (2026). Effect of off-axis osteotomy preparation and depth on intraosseous temperature during implant site preparation: an in vitro study. Journal of Medicine and Palliative Care, 7(3), 562-568. https://doi.org/10.47582/jompac.1900158
Vancouver
Yılmaz T, Yanık S. Effect of off-axis osteotomy preparation and depth on intraosseous temperature during implant site preparation: an in vitro study. Journal of Medicine and Palliative Care. 2026;7(3):562-568. doi:10.47582/jompac.1900158
BibTeX
@article{Ylmaz2026,
author = {Yılmaz, Tolga and Yanık, Saim},
title = {Effect of off-axis osteotomy preparation and depth on intraosseous temperature during implant site preparation: an in vitro study},
journal = {Journal of Medicine and Palliative Care},
year = {2026},
volume = {7},
number = {3},
pages = {562--568},
doi = {10.47582/jompac.1900158}
}