EUVIMEDEUVIMED entdecken
Crossref

AN ANALYSIS ON IMPROVEMENT OF X-RAY DIFFRACTOMETER RESULTS BY CONTROLLING AND CALIBRATION OF PARAMETERS

Hamidreza Moradi, Fatemeh Mehradnia

Advanced Engineering Letters · 2023 · 2 (3) · 105-113

DOI: 10.46793/adeletters.2023.2.3.4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Engineering Letters, 2023. Verfasst von Hamidreza Moradi und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The X-ray diffractometer in the laboratory is a crucial instrument for analyzing materials in science. It can be used on almost any crystal material, and if the machine parameters are appropriately controlled, it can offer a lot of information about the sample’s characteristics. Nevertheless, the data obtained from these machines are complicated by an aberration function that can be resolved through calibration. In this study, a powder comprising of Barium Sulfate (BaSO4), Zinc Oxide (ZnO) and Aluminum (Al) was used as the first sample and a single crystal sample comprised of Gallium Nitride (GaN) and Aluminum Oxide (Al2O3). The required calibration parameters of the X-ray diffractometer namely: Straight Beam Alignment, Beam Cut Alignment and Sample Tilt Alignment for two samples were analyzed and carried out. Using the results of the X-ray spectrum, important parameters such as corresponding planes for peak positions, d-spacing of planes, intensities, smallest crystallite sizes and lattice parameters, and a comparison with the reference data were all carried out. As another result, the out-of-plane alignment and Full-Width- at Half-Maximum (FWHM) value for GaN could be determined using the rocking curve.

Zitieren

APA

Moradi, H., & Mehradnia, F. (2023). AN ANALYSIS ON IMPROVEMENT OF X-RAY DIFFRACTOMETER RESULTS BY CONTROLLING AND CALIBRATION OF PARAMETERS. Advanced Engineering Letters, 2(3), 105-113. https://doi.org/10.46793/adeletters.2023.2.3.4

Vancouver

Moradi H, Mehradnia F. AN ANALYSIS ON IMPROVEMENT OF X-RAY DIFFRACTOMETER RESULTS BY CONTROLLING AND CALIBRATION OF PARAMETERS. Advanced Engineering Letters. 2023;2(3):105-113. doi:10.46793/adeletters.2023.2.3.4

BibTeX
@article{Moradi2023,
  author = {Moradi, Hamidreza and Mehradnia, Fatemeh},
  title = {AN ANALYSIS ON IMPROVEMENT OF X-RAY DIFFRACTOMETER RESULTS BY CONTROLLING AND CALIBRATION OF PARAMETERS},
  journal = {Advanced Engineering Letters},
  year = {2023},
  volume = {2},
  number = {3},
  pages = {105--113},
  doi = {10.46793/adeletters.2023.2.3.4}
}
Kostenlos starten →