Performance improvement of an X-ray ionization beam position monitor for soft X-ray free-electron lasers
Journal of Synchrotron Radiation · 01.07.2026 · 33 (4) · 921-930
DOI: 10.1107/s1600577526005382 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Synchrotron Radiation, online erschienen am 18.06.2026. Verfasst von SunMin Hwang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Pohang Accelerator Laboratory, POSTECH, Pohang, Gyeongbuk 37673, Republic of Korea. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Information, Communications and Technology (ICT) of Korea.
Abstract (Originalsprache)
An X-ray ionization beam position monitor (XIBPM) has been developed and evaluated for beam position diagnostics at a soft X-ray free-electron laser (FEL). The redesign was guided by electrostatic simulations and focused on mitigating electric-field distortions near the microchannel plate (MCP) and improving the internal electrode geometry and structural stability. The introduction of a conductive shielding cover effectively suppressed electric-field distortion from the MCP lead, substantially reducing displacement errors and improving measurement stability. A mesh-free electrode structure was also investigated, reducing photo-ion loss and increasing photo-ion transmission; however, under high-intensity FEL operation, the enhanced signal amplitude occasionally led to saturation effects. Beam position measurements were performed at photon energies of 500–1100 eV in both pink-beam and mono-beam modes. Under optimized conditions, a beam position resolution of approximately 24–25 µm was achieved for pulse-by-pulse analysis and improved to approximately 10–12 µm when averaging over ten pulses. The transverse ion profiles were found to be significantly broader than the actual photon beam size, reflecting intrinsic ion-transport dynamics and detector point-spread effects that dominate over the intrinsic photon beam size. These results demonstrate that the shielding cover represents the most significant improvement for accurate and stable beam position monitoring, while the electrode configuration can be selected flexibly depending on the operating regime. The improved XIBPM provides a practical, non-invasive solution for beam position diagnostics in soft X-ray FEL beamlines.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Pohang Accelerator Laboratory, POSTECH, Pohang, Gyeongbuk 37673, Republic of Korea.
ORCID-Profile: SunMin Hwang, Seonghan Kim, Seungcheol Lee, Hoyoung Jang, Sanghan Park, HyoJung Hyun
Förderung
- Ministry of Science and Information, Communications and Technology (ICT) of Korea
Zitieren
APA
Hwang, S., Kim, S., Song, W., Lee, S., Hahn, G., Jang, H., Jeong, M., Kang, G., Park, S., & Hyun, H. (2026). Performance improvement of an X-ray ionization beam position monitor for soft X-ray free-electron lasers. Journal of Synchrotron Radiation, 33(4), 921-930. https://doi.org/10.1107/s1600577526005382
Vancouver
Hwang S, Kim S, Song W, Lee S, Hahn G, Jang H, et al. Performance improvement of an X-ray ionization beam position monitor for soft X-ray free-electron lasers. Journal of Synchrotron Radiation. 2026;33(4):921-930. doi:10.1107/s1600577526005382
BibTeX
@article{Hwang2026,
author = {Hwang, SunMin and Kim, Seonghan and Song, Woojin and Lee, Seungcheol and Hahn, Garam and Jang, Hoyoung and Jeong, Minzy and Kang, Gyeongbo and Park, Sanghan and Hyun, HyoJung},
title = {Performance improvement of an X-ray ionization beam position monitor for soft X-ray free-electron lasers},
journal = {Journal of Synchrotron Radiation},
year = {2026},
volume = {33},
number = {4},
pages = {921--930},
doi = {10.1107/s1600577526005382}
}
EUVIMED