EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Virtual non-contrast images from dual-layer spectral CT: comparison with true non-contrast across abdominal structures

Domenico De Santis, Antonella Del Gaudio, Benedetta Masci, Bianca Catalano, Marta Zerunian, Michela Polici, Francesco Pucciarelli, Giuseppe Tremamunno, Tiziano Polidori, Ettore Squillaci, Cesare Maino, Davide Ippolito und 2 weitere

European Radiology · 03.06.2026 · 36 (10) · 7718-7730

DOI: 10.1007/s00330-026-12642-0 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Radiology, online erschienen am 03.06.2026. Verfasst von Domenico De Santis und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical-Surgical Sciences and Translational Medicine, School of Medicine and Psychology, Sant'Andrea University Hospital, Sapienza Univ…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiography, Abdominal, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare virtual non-contrast (VNC) images derived from arterial (VNC_A) and portal venous phase (VNC_P) of dual-layer spectral CT (DLCT) with true non-contrast (TNC) images in abdominal imaging, assessing attenuation accuracy, image quality, lesion and calcification measurements, and the potential of VNC to replace TNC in routine protocols. Materials and methods One hundred consecutive patients undergoing triphasic abdominal CT were included. TNC, arterial, and portal venous phases were acquired on a DLCT scanner. VNC_A and VNC_P images were generated using a two-material decomposition algorithm. Attenuation values, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion and calcification metrics were measured. Subjective image quality and diagnostic acceptability were graded by three radiologists. Agreement with TNC was evaluated using ICC, Bland–Altman analysis, ANOVA, and non-parametric tests. Radiation dose reduction achievable by omitting the TNC phase was also assessed.

Results

Although VNC_A showed better agreement with TNC than VNC_P, both consistently underestimated parenchymal and lesion attenuation; lesion size was preserved (12.2 ± 7.9 mm; p = 0.996). Calcification density was significantly reduced in both VNC phases, and calcification diameter was slightly underestimated in VNC_A ( p < 0.001). VNC images demonstrated higher or similar SNR and CNR but inferior subjective image quality ( p < 0.001), due to blotchier appearance. Only 12% of VNC_P datasets were judged fully interchangeable with TNC. Replacing TNC with VNC would yield a 33% radiation dose reduction in this specific protocol.

Conclusions

VNC cannot replace TNC based on the current evidence; further refinements are required for broader clinical adoption. Key Points Question True non-contrast images (TNC) are essential in abdominal CT, yet it remains unclear whether spectral CT-derived virtual non-contrast images (VNC) can reliably replace TNC imaging.

Findings

VNC images approximate TNC images but introduce consistent attenuation biases, reduced subjective quality, and altered calcification metrics, preventing full replacement of dedicated non-contrast acquisitions. Clinical relevance Replacing TNC with VNC images reduces radiation exposure, yet current VNC performance shows measurable differences from TNC, indicating that algorithmic refinement is required before routine diagnostic use in abdominal CT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedRadiography, AbdominalRadiographic Image Interpretation, Computer-AssistedHumansFemaleMaleAlgorithmsMiddle AgedAgedReproducibility of ResultsSignal-To-Noise RatioContrast MediaAdultAged, 80 and overSensitivity and SpecificityRadiation Dosage

Stichwörter der Autor:innen

AbdomenCalcificationsComputed tomographySpectral CTVirtual non-contrast imaging

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Medical-Surgical Sciences and Translational Medicine, School of Medicine and Psychology, Sant'Andrea University Hospital, Sapienza University of Rome, Rome, Italy.
  • PhD School in Translational Medicine and Oncology, Department of Medical and Surgical Sciences and Translational Medicine, Faculty of Medicine and Psychology, Sapienza University of Rome, Rome, Italy.
  • Unità Operativa Complessa di Diagnostica per Immagini e Radiologia Interventistica, Ospedale Isola Tiberina-Gemelli Isola, Rome, Italy.
  • Department of Diagnostic Radiology, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy.
  • Department of Medical-Surgical Sciences and Translational Medicine, School of Medicine and Psychology, Sant'Andrea University Hospital, Sapienza University of Rome, Rome, Italy. marco.francone@uniroma1.it.

Zitieren

APA

De Santis, D., Del Gaudio, A., Masci, B., Catalano, B., Zerunian, M., Polici, M., Pucciarelli, F., Tremamunno, G., Polidori, T., Squillaci, E., Maino, C., Ippolito, D., Francone, M., & Caruso, D. (2026). Virtual non-contrast images from dual-layer spectral CT: comparison with true non-contrast across abdominal structures. European Radiology, 36(10), 7718-7730. https://doi.org/10.1007/s00330-026-12642-0

Vancouver

De Santis D, Del Gaudio A, Masci B, Catalano B, Zerunian M, Polici M, et al. Virtual non-contrast images from dual-layer spectral CT: comparison with true non-contrast across abdominal structures. European Radiology. 2026;36(10):7718-7730. doi:10.1007/s00330-026-12642-0

BibTeX
@article{DeSantis2026,
  author = {De Santis, Domenico and Del Gaudio, Antonella and Masci, Benedetta and Catalano, Bianca and Zerunian, Marta and Polici, Michela and Pucciarelli, Francesco and Tremamunno, Giuseppe and Polidori, Tiziano and Squillaci, Ettore and Maino, Cesare and Ippolito, Davide and Francone, Marco and Caruso, Damiano},
  title = {Virtual non-contrast images from dual-layer spectral CT: comparison with true non-contrast across abdominal structures},
  journal = {European Radiology},
  year = {2026},
  volume = {36},
  number = {10},
  pages = {7718--7730},
  doi = {10.1007/s00330-026-12642-0}
}
Kostenlos starten →