EUVIMEDEUVIMED entdecken
Open Access

Redo-TAVI with SAPIEN 3 in SAPIEN XT or SAPIEN 3 – impact of pre- and post-dilatation on final THV expansion

David Meier, Uri Landes, Lars Sondergaard, Ole De Backer, Georg Lutter, Thomas Puehler, Mariama Akodad, Georgios Tzimas, Philipp Blanke, Geoffrey W Payne, Althea Lai, Hacina Gill und 4 weitere

EuroIntervention · 2023-11 · 19 (9) · 757-765

DOI: 10.4244/eij-d-23-00308 ↗

Kurz gefasst

Fachartikel in der Zeitschrift EuroIntervention, 2023-11. Verfasst von David Meier und 15 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Cardiovascular Innovation, St Paul's Hospital, Vancouver, BC, Canada and Vancouver General Hospital, Vancouver, BC, Canada. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Aortic Valve Insufficiency, Aortic Valve Stenosis, Heart Valve Prosthesis. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: When a balloon-expandable transcatheter heart valve (THV) is chosen to treat a failed balloon-expandable THV, there is a risk of underexpansion with a potential impact on performance. AIMS: We aimed to assess the impact of pre- and post-dilatation on the expansion of balloon-expandable THVs after redo-transcatheter aortic valve implantation (TAVI). METHODS: Redo-TAVI was performed on the bench with a 23 mm SAPIEN 3 (S3) implanted within a 23 mm SAPIEN XT (SXT) or a 23 mm S3, both of which served as the "failed" THVs. Pre- and/or post-dilatation was performed using a 23 mm non-compliant TRUE balloon. Expansion of the index and redo-THVs were assessed before and after pre-/post-dilatation using microcomputed tomography (micro-CT), and THV hydrodynamic testing was conducted. RESULTS: Without pre- or post-dilatation, the S3 was underexpanded, for all combinations, particularly in the mid-portion of the THV (18.6 mm and 19.7 mm representing 81% and 86% of the nominal diameter inside the SXT and S3, respectively). Pre- and post-dilatation had an additive effect on diameter expansion of the redo-THV, which remained constrained in most combinations. The only combination to achieve nominal expansion was the S3 in S3 when both pre- and post-dilatation were performed. The S3 remained underexpanded inside the SXT despite pre- and post-dilatation (93% in the mid-portion). Improved redo-THV expansion was accompanied by 2.7 mm (12%) overexpansion of the index THV. While all samples had acceptable hydrodynamic performance, the underexpanded samples had worse leaflet pinwheeling. CONCLUSIONS: When performing redo-TAVI with a 23 mm S3 inside a 23 mm SXT or S3, only the S3 in S3 with the use of pre- and post-dilatation reached full expansion. This underlines the importance of CT assessment of THV expansion and the role of pre-/post-dilatation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic Valve InsufficiencyAortic Valve StenosisHeart Valve ProsthesisHumansX-Ray MicrotomographyDilatationTreatment OutcomeAortic ValveProsthesis Design

Autor:innen und Institutionen

  • Centre for Cardiovascular Innovation, St Paul's Hospital, Vancouver, BC, Canada and Vancouver General Hospital, Vancouver, BC, Canada.
  • Cardiovascular Translational Laboratory, Vancouver, BC, Canada and Providence Research & Centre for Heart Lung Innovation, Vancouver, BC, Canada.
  • Centre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, BC, Canada.
  • Edith Wolfson Medical Center, Holon, Israel.
  • Rabin Medical Center, Petah Tikva, Israel and Tel Aviv University, Tel Aviv, Israel.
  • Abbott Structural Heart, Santa Clara, CA, USA.

Zitieren

APA

Meier, D., Landes, U., Sondergaard, L., De Backer, O., Lutter, G., Puehler, T., Akodad, M., Tzimas, G., Blanke, P., Payne, G. W., Lai, A., Gill, H., Wood, D. A., Webb, J. G., Sellers, S. L., & Sathananthan, J. (2023). Redo-TAVI with SAPIEN 3 in SAPIEN XT or SAPIEN 3 – impact of pre- and post-dilatation on final THV expansion. EuroIntervention, 19(9), 757-765. https://doi.org/10.4244/eij-d-23-00308

Vancouver

Meier D, Landes U, Sondergaard L, De Backer O, Lutter G, Puehler T, et al. Redo-TAVI with SAPIEN 3 in SAPIEN XT or SAPIEN 3 – impact of pre- and post-dilatation on final THV expansion. EuroIntervention. 2023;19(9):757-765. doi:10.4244/eij-d-23-00308

BibTeX
@article{Meier2023,
  author = {Meier, David and Landes, Uri and Sondergaard, Lars and De Backer, Ole and Lutter, Georg and Puehler, Thomas and Akodad, Mariama and Tzimas, Georgios and Blanke, Philipp and Payne, Geoffrey W and Lai, Althea and Gill, Hacina and Wood, David A and Webb, John G and Sellers, Stephanie L and Sathananthan, Janarthanan},
  title = {Redo-TAVI with SAPIEN 3 in SAPIEN XT or SAPIEN 3 – impact of pre- and post-dilatation on final THV expansion},
  journal = {EuroIntervention},
  year = {2023},
  volume = {19},
  number = {9},
  pages = {757--765},
  doi = {10.4244/eij-d-23-00308}
}
Kostenlos starten →