Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Natsuko Satomi und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Aortic Valve, Aortic Valve Stenosis, Heart Valve Prosthesis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Evidence on structural valve deterioration (SVD) after aortic valve neocuspidization (AVNeo) remains limited. While transcatheter aortic valve replacement (TAVR) offers a less invasive option, its feasibility is unclear. This study aimed to characterize SVD patients post‐AVNeo and to assess TAVR feasibility.

Methods

This retrospective study included 11 patients who underwent TAVR for SVD after AVNeo in Sendai Kousei Hospital between June 2017 and August 2024. Four patients with aortic stenosis (AS) and seven with aortic regurgitation (AR) due to SVD were included.

Results

AS‐SVD group showed shorter time interval from AVNeo to TAVR (50.5 [28.3–98.3] vs. 107.0 [97.0–131.0] months, p = 0.04) and smaller aortic annulus area (316.5 [259.8–375.0] vs. 538.0 [440.0–582.0] mm 2 , p = 0.005) than AR‐SVD group. In TAVR, technical success was achieved in 91% of cases. Although coronary obstruction is a concern due to the long leaflet, no case occurred. Misidentification of the basal ring plane caused by the slack cusp resulted in second valve implantation (one case) and new conduction disturbance (two cases) due to deep implantation, and aortic contained rupture (one case) for oversized valve selection.

Conclusions

Rapid AS‐SVD progression and AR‐SVD occurring later than previously reported were observed, highlighting the need for further studies on AVNeo durability. TAVR after AVNeo was feasible. Special precautions for coronary obstruction may be unnecessary. Careful hinge point placement at the boundary between pericardial cusps and the annulus was a key to CT‐based basal ring determination in patients after AVNeo.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic ValveAortic Valve StenosisHeart Valve ProsthesisAortic Valve InsufficiencyProsthesis FailureHumansRetrospective StudiesMaleFemaleTreatment OutcomeTime FactorsAged, 80 and overAgedFeasibility StudiesProsthesis DesignRisk FactorsJapan

Stichwörter der Autor:innen

aortic valve neocuspidizationcoronary obstructionstructural valve degenerationtranscatheter aortic valve replacement

Autor:innen und Institutionen

  • Department of Cardiology, Sendai Kousei Hospital, Miyagi, Japan.
  • Department of Laboratory Medicine, The Jikei University School of Medicine, Tokyo, Japan.
  • Department of Cardiovascular Surgery, Yamagata Prefectural Central Hospital, Yamagata, Japan.
  • Department of Health Data Science, Tokyo Medical University, Tokyo, Japan.
  • Department of Cardiovascular Surgery, Sendai Kousei Hospital, Miyagi, Japan.

ORCID-Profile: Natsuko Satomi, Masaki Miyasaka, Yusuke Enta, Masaki Nakashima, Masataka Taguri, Yukihiro Hayatsu, Norio Tada

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Satomi, N., Miyasaka, M., Enta, Y., Munehisa, Y., Toki, Y., Nakashima, M., Saigan, M., Kobayashi, Y., Teng, Y., Maeda, M., Kosuga, M., Abe, K., Taguri, M., Hayatsu, Y., Hata, M., & Tada, N. (2025). Transcatheter Aortic Valve Replacement for Structural Valve Deterioration After Aortic Valve Neocuspidization. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31583

Vancouver

Satomi N, Miyasaka M, Enta Y, Munehisa Y, Toki Y, Nakashima M, et al. Transcatheter Aortic Valve Replacement for Structural Valve Deterioration After Aortic Valve Neocuspidization. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31583

BibTeX
@article{Satomi2025,
  author = {Satomi, Natsuko and Miyasaka, Masaki and Enta, Yusuke and Munehisa, Yoshiko and Toki, Yusuke and Nakashima, Masaki and Saigan, Makoto and Kobayashi, Yuta and Teng, Yun and Maeda, Manabu and Kosuga, Momo and Abe, Kazuo and Taguri, Masataka and Hayatsu, Yukihiro and Hata, Masaki and Tada, Norio},
  title = {Transcatheter Aortic Valve Replacement for Structural Valve Deterioration After Aortic Valve Neocuspidization},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31583}
}
Kostenlos starten →