EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Impact of balloon post‐dilation on valve durability and long‐term clinical outcomes after self‐expanding transcatheter aortic valve implantation

Jorge Sanz Sánchez iD, Damiano Regazzoli, Marco Barbanti, Claudia Fiorina, Marianna Adamo iD, Marco Angelillis, Marco De Carlo iD, Barbara Bellini, Matteo Montorfano, Antonio Mangieri iD, Giuseppe Bruschi, Bruno Merlanti und 7 weitere

Catheterization and Cardiovascular Interventions · 2024

DOI: 10.1002/ccd.30907 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2024. Verfasst von Jorge Sanz Sánchez und 18 weiteren Autor:innen. Beteiligte Einrichtung: Humanitas Clinical and Research Center, IRCCS, Milan, Italy. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Heart Valve Prosthesis, Aortic Valve Stenosis. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Balloon post‐dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long‐term clinical outcomes and valve hemodynamics is yet unknown.

Aims

To evaluate the impact of BPD on valve durability and long‐term clinical outcomes in patients undergoing self‐expanding transcatheter valve implantation (TAVI).

Methods

Echocardiographic and clinical data from the ClinicalService (a nation‐based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all‐cause death and SVD. Cumulative incidence functions for SVD were estimated.

Results

Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6‐year follow‐up were found between groups in terms of all‐cause mortality (HR: 1.05, 95% CI: 0.9–1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6‐year follow‐up.

Conclusions

BPD following TAVI with a self‐expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6‐year follow‐up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementHeart Valve ProsthesisAortic Valve StenosisHumansDilatationTreatment OutcomeAortic ValveProsthesis Design

Stichwörter der Autor:innen

TAVIballoon post-dilationvalve degeneration plusvalve durability

Autor:innen und Institutionen

  • Humanitas Clinical and Research Center, IRCCS, Milan, Italy.
  • Hospital Universitari i Politecnic La Fe, Valencia, Spain.
  • Università degli Studi di Enna "Kore", Enna, Italy.
  • Cardiac Catheterization Laboratory and Cardiology, ASST Spedali Cividi di Brescia, Brescia, Italy.
  • Cardiothoracic and Vascular Department, Pisa University Hospital, Pisa, Italy.
  • Interventional Cardiology Unit, Cardio-Thoracic-Vascular Department, San Raffaele Scientific Institute, Milan, Italy.

ORCID-Profile: Jorge Sanz Sánchez, Marianna Adamo, Marco De Carlo, Antonio Mangieri, Luca Testa, Carmine Musto

Zitieren

APA

Sanz Sánchez, J., Regazzoli, D., Barbanti, M., Fiorina, C., Adamo, M., Angelillis, M., De Carlo, M., Bellini, B., Montorfano, M., Mangieri, A., Bruschi, G., Merlanti, B., Agnifili, M. L., Testa, L., Ferrara, E., Musto, C., Colombo, A., Tamburino, C., & Reimers, B. (2024). Impact of balloon post‐dilation on valve durability and long‐term clinical outcomes after self‐expanding transcatheter aortic valve implantation. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.30907

Vancouver

Sanz Sánchez J, Regazzoli D, Barbanti M, Fiorina C, Adamo M, Angelillis M, et al. Impact of balloon post‐dilation on valve durability and long‐term clinical outcomes after self‐expanding transcatheter aortic valve implantation. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.30907

BibTeX
@article{SanzSnchez2024,
  author = {Sanz Sánchez, Jorge and Regazzoli, Damiano and Barbanti, Marco and Fiorina, Claudia and Adamo, Marianna and Angelillis, Marco and De Carlo, Marco and Bellini, Barbara and Montorfano, Matteo and Mangieri, Antonio and Bruschi, Giuseppe and Merlanti, Bruno and Agnifili, Mauro Luca and Testa, Luca and Ferrara, Erica and Musto, Carmine and Colombo, Antonio and Tamburino, Corrado and Reimers, Bernhard},
  title = {Impact of balloon post‐dilation on valve durability and long‐term clinical outcomes after self‐expanding transcatheter aortic valve implantation},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  doi = {10.1002/ccd.30907}
}
Kostenlos starten →