Rapid retrieval of fractured implant abutment screws with a custom-made screwdriver
Journal of Dental Sciences · 2023-10 · 18 (4) · 1952-1955
DOI: 10.1016/j.jds.2023.05.028 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Dental Sciences, 2023-10. Verfasst von Ming-Shu Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, National Taiwan University, Taipei, Taiwan. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
tps://doi.org/10.1016/j.jds.2023.05. 91-7902/a 2023 Association for Denta e CC BY-NC-ND license (http://creati The success rate of dental implant is high and some of them are free of complications. However, screw loosening, especially for single implant-retained crowns, is the second most common technical complication proceeded by veneering material wear or chipping. Frequent screw loosening may lead to the screw fracture. With recent advances in implant design and material strength improvement, the incidences of screw loosening and screw fracture of implant-supported single crowns over a 5-year period are 8.8% and 0.18%, respectively. The difficulty of retrieving a fractured screw depends on the mobility of the fractured fragment, the type of abutment connection, and the level of fracture. Fortunately, the fractured screw fragments are frequently loose in the implant. Screw fracture usually occurs at the junction of the screw head and the shank or where the threaded portion begins. Various methods for retrieving fractured screw are reported. Most of them are time-consuming and risky. In this article, we demonstrated an efficient and safe method for retrieving the fractured abutment screws using a custom-made screwdriver modified from an 18-gauge syringe needle. Clinical procedures for retrieving the fractured abutment screws using a custom-made screwdriver were described as follows: (1) Check the condition of the implant and soft tissue and verify the level of the fractured screw with periapical radiographs (Fig. 1A and B). (2) Confirm the accessibility of the screw fragments. If
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Dentistry, National Taiwan University, Taipei, Taiwan.
- Department of Prosthodontics, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan.
- Department of Dentistry, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan.
- Department of Dentistry, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan.
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan.
- Department of Orthodontics, Far Eastern Memorial Hospital, New Taipei City, Taiwan.
Zitieren
APA
Lee, M. S., Chiang, C. P., Tseng, W. Y., & Ho, C. J. (2023). Rapid retrieval of fractured implant abutment screws with a custom-made screwdriver. Journal of Dental Sciences, 18(4), 1952-1955. https://doi.org/10.1016/j.jds.2023.05.028
Vancouver
Lee MS, Chiang CP, Tseng WY, Ho CJ. Rapid retrieval of fractured implant abutment screws with a custom-made screwdriver. Journal of Dental Sciences. 2023;18(4):1952-1955. doi:10.1016/j.jds.2023.05.028
BibTeX
@article{Lee2023,
author = {Lee, Ming-Shu and Chiang, Chun-Pin and Tseng, Wan-Yu and Ho, Chih-Liang Julian},
title = {Rapid retrieval of fractured implant abutment screws with a custom-made screwdriver},
journal = {Journal of Dental Sciences},
year = {2023},
volume = {18},
number = {4},
pages = {1952--1955},
doi = {10.1016/j.jds.2023.05.028}
}
EUVIMED