Comparison of Rebound (iCare) and Noncontact Tonometer in Intraocular Pressure Measurement in Adults – A Literature Review

Maghalakshmi Udhayakumar Naidu, S. Ashok Vardhan

Journal of Ophthalmology Clinics and Research · 2023-07 · 3 (2) · 23-27

DOI: 10.4103/jocr.jocr_5_26 ↗

At a glance

Journal article in Journal of Ophthalmology Clinics and Research, published online on 2026-07-14. Written by Maghalakshmi Udhayakumar Naidu and 1 co-authors. 20 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Glaucoma is defined as a chronic progressive optic neuropathy due to damage to the retinal ganglion cells and axons, leading to specific visual field defects and potential permanent blindness. Hence, detecting glaucoma early is important. The only modifiable risk factor of glaucoma is the intraocular pressure (IOP). Selection of a tonometer that gives accurate and reasonable IOP measurements, which is convenient to use, easier to standardize, and simple to calibrate, is essential. The objective of this study was to compare the accuracy, agreement, and clinical utility of iCare and noncontact tonometer (NCT) in measuring IOP, particularly in the context of their suitability for routine clinical use and community-based glaucoma screening. A comprehensive literature search was conducted across multiple electronic databases, included PubMed and Google Scholar, to ensure broad and inclusive coverage of relevant studies. The search strategy, using a combination of medical subject headings terms and free-text keywords, was developed. The primary search terms included “intraocular pressure,” “tonometry,” “rebound tonometer,” “iCare,” “noncontact tonometer,” and “NCT.” Both rebound tonometers (iCare) and noncontact tonometers are useful for screening, but Goldmann applanation tonometry confirmation remains essential.

Cite

APA

Naidu, M. U., & Vardhan, S. A. (2023). Comparison of Rebound (iCare) and Noncontact Tonometer in Intraocular Pressure Measurement in Adults – A Literature Review. Journal of Ophthalmology Clinics and Research, 3(2), 23-27. https://doi.org/10.4103/jocr.jocr_5_26

Vancouver

Naidu MU, Vardhan SA. Comparison of Rebound (iCare) and Noncontact Tonometer in Intraocular Pressure Measurement in Adults – A Literature Review. Journal of Ophthalmology Clinics and Research. 2023;3(2):23-27. doi:10.4103/jocr.jocr_5_26

BibTeX
@article{Naidu2023,
  author = {Naidu, Maghalakshmi Udhayakumar and Vardhan, S. Ashok},
  title = {Comparison of Rebound (iCare) and Noncontact Tonometer in Intraocular Pressure Measurement in Adults – A Literature Review},
  journal = {Journal of Ophthalmology Clinics and Research},
  year = {2023},
  volume = {3},
  number = {2},
  pages = {23--27},
  doi = {10.4103/jocr.jocr_5_26}
}