Comparison of intraocular pressure measured by iCare tonometers and Goldmann applanation tonometer
Canadian Journal of Ophthalmology · 2023-10 · 58 (5) · 426-432
DOI: 10.1016/j.jcjo.2022.06.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Canadian Journal of Ophthalmology, 2023-10. Verfasst von Robin Sachdeva und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ivey Eye Institute, St. Joseph Healthcare, London, Ont. Hauptthemen laut MEDLINE: Glaucoma, Ocular Hypertension. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Lawson Health Research Institute.
Abstract (Originalsprache)
OBJECTIVE: To evaluate the relationship between the Goldmann applanation tonometer (GAT) and the iCare PRO and iCare IC200 tonometers in measuring intraocular pressure (IOP) in adult eyes with a diagnosis of glaucoma or glaucoma suspect. PARTICIPANTS AND METHODS: One hundred and one eyes from 101 participants diagnosed with glaucoma or glaucoma suspect were evaluated in this study. IOP was measured by iCare PRO and iCare IC200 tonometers in a randomized sequence followed by IOP measurements by the GAT tonometer and then central corneal thickness measurements. After the IOP measurements, participants scored their comfort level using a visual analog scale with each tonometer. Intraclass correlation coefficient (ICC) and Bland-Altman analysis were used to investigate the agreement among tonometers. SPSS and Microsoft Excel programs were used for statistical analysis. RESULTS: Overall, there was good agreement among the 3 tonometers used in this study. The ICC for the iCare PRO and the iCare IC200 was 0.95 (p 0.80 (p < 0.001). However, both iCare tonometers underestimated IOP by approximately 2 mm Hg compared with the GAT. Furthermore, 84% of iCare readings fall within ±5 mm Hg of GAT measurements. Neither body mass index nor central corneal thickness affected the IOP agreement among the tonometers. Participant response on visual analog scale rated IOP measurements by iCare tonometers to be more comfortable than the GAT. CONCLUSION: Our results demonstrated a good agreement between iCare tonometers and GAT; but iCare tonometers underestimated IOP compared to the GAT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Ivey Eye Institute, St. Joseph Healthcare, London, Ont.
- Department of Ophthalmology, Western University, London, Ont.
Förderung
- Lawson Health Research Institute
Zitieren
APA
Sachdeva, R., Iordanous, Y., & Lin, T. (2023). Comparison of intraocular pressure measured by iCare tonometers and Goldmann applanation tonometer. Canadian Journal of Ophthalmology, 58(5), 426-432. https://doi.org/10.1016/j.jcjo.2022.06.002
Vancouver
Sachdeva R, Iordanous Y, Lin T. Comparison of intraocular pressure measured by iCare tonometers and Goldmann applanation tonometer. Canadian Journal of Ophthalmology. 2023;58(5):426-432. doi:10.1016/j.jcjo.2022.06.002
BibTeX
@article{Sachdeva2023,
author = {Sachdeva, Robin and Iordanous, Yiannis and Lin, Tony},
title = {Comparison of intraocular pressure measured by iCare tonometers and Goldmann applanation tonometer},
journal = {Canadian Journal of Ophthalmology},
year = {2023},
volume = {58},
number = {5},
pages = {426--432},
doi = {10.1016/j.jcjo.2022.06.002}
}
EUVIMED