Marginal gap of three-dimensional printed full-arch frameworks supported by all-on-four and all-on-six implant designs
The Journal of Indian Prosthodontic Society · 2025-07 · 25 (3) · 191-197
DOI: 10.4103/jips.jips_40_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Indian Prosthodontic Society, online erschienen am 16.07.2025. Verfasst von Leticia Del Rio Silva und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Dental Prosthesis Design, Dental Marginal Adaptation, Dental Implants. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Aim
The aim of this study was to evaluate the marginal gap of full-arch frameworks (FAFs) supported by all-on-four and all-on-six implant designs, fabricated using different manufacturing technologies. Settings and Design: This was an in vitro study. Materials and Methods: Fifteen titanium FAFs were fabricated using milling and three-dimensional printing techniques: selective laser melting (SLM) and electron beam melting (EBM) ( n = 5/group). The marginal gap between the framework and abutment was measured using a microscope with 1 μm accuracy. Measurements were taken three times by a calibrated examiner (intraclass correlation coefficient of 0.996; P < 0.001) at the buccal and lingual interface between the abutment and the framework. Statistical Analysis Used: A two-way ANOVA was applied to assess the effects of implant design and manufacturing technology (α = 0.05).
Results
When comparing implant designs, the all-on-four group (milling [ P = 0.002] and SLM [ P = 0.001]) exhibited lower marginal gap values than the all-on-six group. No statistically significant difference was observed between the EBM frameworks in both designs. In the all-on-four group, milling resulted in lower marginal gap values than SLM ( P = 0.021) and EBM ( P = 0.001), while no statistically significant difference was found between the SLM and EBM groups ( P = 0.163). For the all-on-six framework design, the milling ( P = 0.008) and EBM ( P < .001) groups exhibited lower marginal gap values than the SLM group. No statistically significant difference was detected between the milling and EBM groups ( P = 0.160).
Conclusion
Milled frameworks should be the preferred choice for rehabilitations using the all-on-four implant design. For the all-on-six design, both milled and EBM frameworks may be indicated. The marginal gap values observed for all FAFs designs and manufacturing technologies can be considered clinically acceptable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil.
Zitieren
APA
Silva, L. D. R., Barbin, T., Velôso, D. V., Mesquita, M. F., & Borges, G. A. (2025). Marginal gap of three-dimensional printed full-arch frameworks supported by all-on-four and all-on-six implant designs. The Journal of Indian Prosthodontic Society, 25(3), 191-197. https://doi.org/10.4103/jips.jips_40_25
Vancouver
Silva LDR, Barbin T, Velôso DV, Mesquita MF, Borges GA. Marginal gap of three-dimensional printed full-arch frameworks supported by all-on-four and all-on-six implant designs. The Journal of Indian Prosthodontic Society. 2025;25(3):191-197. doi:10.4103/jips.jips_40_25
BibTeX
@article{Silva2025,
author = {Silva, Leticia Del Rio and Barbin, Thaís and Velôso, Daniele Valente and Mesquita, Marcelo Ferraz and Borges, Guilherme Almeida},
title = {Marginal gap of three-dimensional printed full-arch frameworks supported by all-on-four and all-on-six implant designs},
journal = {The Journal of Indian Prosthodontic Society},
year = {2025},
volume = {25},
number = {3},
pages = {191--197},
doi = {10.4103/jips.jips_40_25}
}
EUVIMED