Misfit simulation on implant-supported prostheses with different combinations of engaging and nonengaging titanium bases: Part 3: A radiographic evaluation
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2024.01.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Vygandas Rutkunas und 6 weiteren Autor:innen. Beteiligte Einrichtung: Professor, Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania; and Director, Digitoru…. Hauptthemen laut MEDLINE: Dental Prosthesis, Implant-Supported, Titanium, Dental Materials, Dental Marginal Adaptation. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The fit of implant-supported prostheses plays an important role in their mechanical and biological stability. Clinically, the prosthetic fit is typically assessed radiographically, but this method relies on the operator's subjective evaluation. Whether available digital tools could optimize the evaluation of the prosthetic fit is uncertain. PURPOSE: The purpose of this in vitro study was to evaluate the influence of an image processing program on the radiographic detection of discrepancies in the active and passive fit of implant-supported prostheses. Two-implant-supported screw-retained prostheses were analyzed by simulating the vertical and horizontal misfits of 3 different implant abutment configurations. MATERIAL AND METHODS: Seven casts were fabricated using 2 internal-connection titanium implants: 1 control; 3 with vertical (V) misfit of 50 µm, 100 µm, 150 µm; and 3 with horizontal (H) misfit of 35 µm, 70 µm, 100 µm. Thirty bar-shaped zirconia frameworks were fabricated and divided into 3 groups (n=10) according to their attachment to 2 engaging (E-E), 2 nonengaging (NE-NE), and engaging and nonengaging (E-NE) titanium bases. Digital parallel periapical radiographs were made of each specimen in the passive and active fit situation on each cast (1-screw test), except for the E-E specimens, which were only seated on the control, H35, and H70 casts because the fit on the remaining casts was poor. The mean gray value (MGV) was measured at the chosen regions of interest on the second implant (side B) using the ImageJ software program. Differences in the MGV measurements between the passive and active conditions were tested using a t test (α=.05) and compared the different misfit levels using analysis of variance (1-way ANOVA), followed by the Tukey HSD test (α=.05). RESULTS: The highest values for the differences between passive and active fit were found for the V150 and H100 misfit simulations (P .05). In the horizontal misfit group of NE-NE abutment configuration, H70 revealed no significant difference from the control group cast (P>.05). CONCLUSIONS: Measuring MGV differences between passive and active fit could be a promising alternative for detecting 70- to 150-µm gaps in the implant-abutment connection that result from the misfit. However, the procedure was not adequate for detecting
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Professor, Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania; and Director, Digitorum Research Center, Vilnius, Lithuania.
- Postgraduate student, Department of Periodontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania; and Researcher, Digitorum Research Center, Vilnius, Lithuania.
- Dental Research Assistant, Department of Dental Medicine and Oral Health, Medical University of Graz, Graz, Austria.
- Attending, Department of Dental Medicine and Oral Health, Medical University of Graz, Graz, Austria.
- Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director, Digital Dentistry, Kois Center, Seattle, Wash.; and…
- Associate Professor, Faculty of Odontology, Malmö University, Malmö, Sweden; and Associate Visiting Professor, Faculty of Dentistry, Department of Prosthetic Dentistry, Riga Stradins University, Riga, Latvia.
Zitieren
APA
Rutkunas, V., Kules, D., Mischitz, I., Huber, S., Revilla-León, M., Larsson, C., & Janda, M. (2025). Misfit simulation on implant-supported prostheses with different combinations of engaging and nonengaging titanium bases: Part 3: A radiographic evaluation. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.01.014
Vancouver
Rutkunas V, Kules D, Mischitz I, Huber S, Revilla-León M, Larsson C, et al. Misfit simulation on implant-supported prostheses with different combinations of engaging and nonengaging titanium bases: Part 3: A radiographic evaluation. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2024.01.014
BibTeX
@article{Rutkunas2025,
author = {Rutkunas, Vygandas and Kules, Daniel and Mischitz, Ingrida and Huber, Sandra and Revilla-León, Marta and Larsson, Christel and Janda, Martin},
title = {Misfit simulation on implant-supported prostheses with different combinations of engaging and nonengaging titanium bases: Part 3: A radiographic evaluation},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2024.01.014}
}
EUVIMED