Additive manufacturing of CAD-CAM complete arch fixed implant restorations supported by six implants: Prosthetic screw stability and marginal precision under masticatory simulation
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2025.04.042 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Daniele Valente Velôso und 5 weiteren Autor:innen. Beteiligte Einrichtung: Research Fellow, Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, …. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Prosthesis, Implant-Supported, Dental Prosthesis Design, Dental Implants. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Coordination of Higher Education Personnel Improvement, State University of Campinas, State of Sao Paulo Research Foundation.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Titanium frameworks for implant-supported fixed prostheses can be fabricated through subtractive or additive manufacturing using computer-aided design and computer-aided manufacturing (CAD-CAM) systems. However, the accuracy achieved by these technologies remains uncertain. PURPOSE: The purpose of this in vitro study was to evaluate complete arch maxillary fixed prostheses supported by 6 implants using CAD-CAM frameworks manufactured by milling and 3D printing technologies, selective laser melting (SLM), and electron beam melting (EBM) on the marginal fit and screw loosening torque before and after masticatory simulation. MATERIAL AND METHODS: Ti-6Al-4V frameworks were manufactured by milling, SLM, and EBM technologies (n=5) and were subsequently ceramic veneered. The surface topography of the framework was assessed by scanning electron microscopy and laser scanning confocal microscopy. One-way analysis of variance (ANOVA) was used to evaluate surface area. The specimens were further evaluated for the dependent variables (marginal fit and screw loosening torque) before and after masticatory simulation. Two-way repeated measures ANOVA and the Pearson correlation were performed (α=.05). RESULTS: Topographical analysis demonstrated that the milling group had a smooth surface (surface area: 1.17 ±0.02 µm2) with regular regions, while additive manufacturing groups showed a dendritic profile with higher surface area (SLM: 1.23 ±0.05 µm2; EBM: 1.21 ±0.03 µm2; P .05) for both dependent variables. Marginal fit showed no further significant differences regarding either the manufacturing technology or the evaluation time. Masticatory simulation reduced screw loosening torque (P=.032). Regarding manufacturing technology, milling resulted in a higher screw loosening torque compared with SLM (P=.01); however, no difference was observed between EBM and either SLM or milling (P>.05). A moderate correlation (P=.02) between marginal fit and screw loosening torque was observed only at baseline for the pooled CAD-CAM (milling, SLM, and EBM) specimens. CONCLUSIONS: CAD-CAM complete arch fixed prostheses on 6 implants made by milling, SLM, and EBM exhibited marginal fit values below the acceptable error limits. Regarding prosthetic screw loosening torque, the pooled milled frameworks showed better values compared with SLM. After masticatory simulation, prosthetic screw stability decreased in all prostheses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Research Fellow, Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo, Brazil.
- Associate Professor, Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo, Brazil.
- Full Professor, Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo, Brazil.
- Postdoctoral student, Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo, Brazil. Electronic address: borgesga@unicamp.br.
Förderung
- Coordination of Higher Education Personnel Improvement
- State University of Campinas
- State of Sao Paulo Research Foundation
- National Council for Scientific and Technological Development
Zitieren
APA
Velôso, D. V., Barbin, T., Del Rio Silva, L., Barão, V. A. R., Mesquita, M. F., & Borges, G. A. (2025). Additive manufacturing of CAD-CAM complete arch fixed implant restorations supported by six implants: Prosthetic screw stability and marginal precision under masticatory simulation. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.04.042
Vancouver
Velôso DV, Barbin T, Del Rio Silva L, Barão VAR, Mesquita MF, Borges GA. Additive manufacturing of CAD-CAM complete arch fixed implant restorations supported by six implants: Prosthetic screw stability and marginal precision under masticatory simulation. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.04.042
BibTeX
@article{Velso2025,
author = {Velôso, Daniele Valente and Barbin, Thaís and Del Rio Silva, Letícia and Barão, Valentim A R and Mesquita, Marcelo Ferraz and Borges, Guilherme Almeida},
title = {Additive manufacturing of CAD-CAM complete arch fixed implant restorations supported by six implants: Prosthetic screw stability and marginal precision under masticatory simulation},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2025.04.042}
}
EUVIMED