EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY-NC-ND 4.0

A comparative evaluation of peri-implant soft and hard tissues between internal hexagonal and internal conical type of implant-abutment connection: A randomized controlled trial

Aditi Mishra, Ramashanker Siddharth, Balendra Pratap Singh, Kamleshwar Singh, Mayank Singh, Pooran Chand

The Journal of Indian Prosthodontic Society · 2026

DOI: 10.4103/jips.jips_248_25 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift The Journal of Indian Prosthodontic Society, 2026. Verfasst von Aditi Mishra und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India. Hauptthemen laut MEDLINE: Dental Implant-Abutment Design, Dental Implants, Single-Tooth. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To compare the effect of internal hexagonal and internal conical implant-abutment connection (IAC) on peri-implant hard and soft tissues. Settings and Design: Parallel arm, randomized controlled trial. Materials and Methods: A total of 44 participants requiring rehabilitation with single implant-supported crown in the posterior region were enrolled and randomly allocated to two groups ( n = 22). Participants in Group 1 were rehabilitated with implants with internal hexagonal IAC while in Group 2 with implants having internal conical IAC. Following delayed loading protocol, implants were restored with single implant-supported crown and baseline data along with subsequent follow up data at 3 rd , 6 th , and 12 th months after occlusal loading were recorded. Statistical Analysis Used: Data were analyzed using the Statistical Packages for Social Sciences (SPSS) version 29.0. Categorical variables were represented as counts/percentages, whereas continuous variables were denoted as mean ± standard deviation. Unpaired t -tests and Chi-square tests were used for group comparisons.

Results

At 12 months, crestal bone loss was lower in the internal conical group (0.78 ± 0.03 mm) than the internal hexagonal group (0.81 ± 0.02 mm; P < 0.001). Probing depth was consistently shallower in the internal conical group (3.17 ± 0.09 mm vs. 3.47 ± 0.17 mm; P < 0.001). Interleukin-1β levels were significantly lower in the internal conical group across all time points, with large effect sizes.

Conclusion

Internal conical IAC showed lower inflammation, improved bone preservation, and shallower probing depths compared to internal hexagonal IAC. Despite small structural effect sizes, the inflammatory response indicated a meaningful biological advantage. Both IAC remain viable, with selection guided by patient-specific needs and long-term outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Implant-Abutment DesignDental Implants, Single-ToothHumansFemaleAlveolar Bone LossMaleCrownsDental Prosthesis, Implant-SupportedAdultMiddle Aged

Stichwörter der Autor:innen

Dental implantMorse taper dental implant-abutment connectiondental implant-abutment connectiondental implant-abutment design

Autor:innen und Institutionen

  • Department of Prosthodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India.
  • Department of Prosthodontics, Crown and Bridge, Faculty of Dental Sciences, King George's Medical University, Lucknow, Uttar Pradesh, India.

Zitieren

APA

Mishra, A., Siddharth, R., Singh, B. P., Singh, K., Singh, M., & Chand, P. (2026). A comparative evaluation of peri-implant soft and hard tissues between internal hexagonal and internal conical type of implant-abutment connection: A randomized controlled trial. The Journal of Indian Prosthodontic Society. https://doi.org/10.4103/jips.jips_248_25

Vancouver

Mishra A, Siddharth R, Singh BP, Singh K, Singh M, Chand P. A comparative evaluation of peri-implant soft and hard tissues between internal hexagonal and internal conical type of implant-abutment connection: A randomized controlled trial. The Journal of Indian Prosthodontic Society. 2026. doi:10.4103/jips.jips_248_25

BibTeX
@article{Mishra2026,
  author = {Mishra, Aditi and Siddharth, Ramashanker and Singh, Balendra Pratap and Singh, Kamleshwar and Singh, Mayank and Chand, Pooran},
  title = {A comparative evaluation of peri-implant soft and hard tissues between internal hexagonal and internal conical type of implant-abutment connection: A randomized controlled trial},
  journal = {The Journal of Indian Prosthodontic Society},
  year = {2026},
  doi = {10.4103/jips.jips_248_25}
}
Kostenlos starten →