The innovative double or triple dental abutment‐implant: Case study with a 3‐ to 12‐year follow‐up
Clinical Advances in Periodontics · 2025
DOI: 10.1002/cap.10300 ↗Kurz gefasst
Fallbericht in der Zeitschrift Clinical Advances in Periodontics, 2025. Verfasst von Luciana Silva Colepícolo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Federal University of Minas Gerais, Institute of Technology and Research (ITP), Belo Horizonte, Minas Gerais, Brazil. Hauptthemen laut MEDLINE: Dental Implant-Abutment Design, Dental Abutments. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben.
Abstract (Originalsprache)
Background
The aim of this case study is to present the rationality and scientific evidence of a new design for a double (DA) and triple (TA) dental abutment‐implant with their specific new concept of biodynamic optimized peri‐implant tissue (BOPiT).
Methods
The innovative design of these abutments with a paraboloid geometry was based on BOPiT, simultaneously involving the principles of mechanobiology, biotensegrity, and mechanotransduction. Thus, 37 consecutive individuals/43 cases rehabilitated with single dental implant using the innovative DA ( n = 28) and TA ( n = 15) on 43 implants were included in this case study. The DA and TA support 2 or 3 dental crowns on a single implant, respectively. Clinic and radiographic examinations were presented at T1 (loading after 4 months) and T2 [final examination with an average follow‐up time of 7.2 years (>3 to 12 years)].
Results
At T2, mean scores for plaque index, peri‐implant bleeding on probing, and peri‐implant probing depth were low, depicting healthy peri‐implant conditions. All radiographic images showed insignificant annual marginal bone loss (0.022 ± 0.05 mm) when compared to T1, reflecting great bone stability.
Conclusion
DA and TA, based on the BOPiT concept, represent an advantageous, simple and non‐invasive mechanism for the longevity and healthy regulation of the peri‐implant tissues.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Federal University of Minas Gerais, Institute of Technology and Research (ITP), Belo Horizonte, Minas Gerais, Brazil.
- Instituto Universitário Italiano de Rosario, Santa Fé, Argentina.
- Private Dental Clinic, Belo Horizonte, Minas Gerais, Brazil.
- School of Dentistry, Department of Periodontology, Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil.
ORCID-Profile: Luciana Silva Colepícolo, Maria Auxiliadora Mourão Martinez, Andrea Augusto Rodrigues, Leonardo Silveira Baeta, Fernando Oliveira Costa
Zitieren
APA
Colepícolo, L. S., Mourão Martinez, M. A., Rodrigues, A. A., Baeta, L. S., & Costa, F. O. (2025). The innovative double or triple dental abutment‐implant: Case study with a 3‐ to 12‐year follow‐up. Clinical Advances in Periodontics. https://doi.org/10.1002/cap.10300
Vancouver
Colepícolo LS, Mourão Martinez MA, Rodrigues AA, Baeta LS, Costa FO. The innovative double or triple dental abutment‐implant: Case study with a 3‐ to 12‐year follow‐up. Clinical Advances in Periodontics. 2025. doi:10.1002/cap.10300
BibTeX
@article{Colepcolo2025,
author = {Colepícolo, Luciana Silva and Mourão Martinez, Maria Auxiliadora and Rodrigues, Andrea Augusto and Baeta, Leonardo Silveira and Costa, Fernando Oliveira},
title = {The innovative double or triple dental abutment‐implant: Case study with a 3‐ to 12‐year follow‐up},
journal = {Clinical Advances in Periodontics},
year = {2025},
doi = {10.1002/cap.10300}
}
EUVIMED