EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY 4.0

Randomized Controlled Clinical Trial Comparing Screw‐Retained Monolithic Zirconia Implant Crowns on Standardized Titanium Base Versus Customized Titanium Abutments– 3‐Years Data

Jenni Hjerppe iD, Stephanie Wenk iD, Shunsuke Fukuba iD, Sven Mühlemann iD, Ronald E Jung iD, Daniel S Thoma iD

Clinical Oral Implants Research · 2026-11 · 37 (11) · 1233-1248

DOI: 10.1111/clr.70165 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 06.08.2026. Verfasst von Jenni Hjerppe und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Zirconium, Titanium, Crowns, Dental Prosthesis, Implant-Supported. Die Arbeit nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dentsply Sirona.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess 3‐year interim results of implant‐supported monolithic zirconia single crowns on standardized titanium base vs. customized titanium abutments. Material and Methods Patients in need of posterior implant were recruited. After implant healing time, patients were randomly allocated to: Ti‐Base ( n = 30) with a monolithic zirconia crown on a standardized Ti‐Base abutment or Custom ( n = 30) with a monolithic zirconia crown on a customized titanium abutment. Implant crowns were evaluated at Baseline (BL), 1‐year (1Y‐FU), and 3 years (3Y‐FU) follow‐ups for marginal bone level changes (MBL), survival, biological and technical outcomes, and PROMs. Chi‐squared and Fisher's exact test were used to assess association between categorical variables, Mann–Whitney's test to compare the distribution of parameters between groups, with a significance level of 5 % (α = 0.05).

Results

Fifty‐one patients (23 Custom, 28 Ti‐Base) attended 3Y‐FU visit. No implant crowns were lost. Similar median MBL changes from BL to 3Y‐FU and comparable biological outcomes were observed in both groups ( p > 0.05). No major technical complications were observed, but one minor chipping of Ti‐Base zirconia crown was recorded at 3Y‐FU, resulting in a technical complication rate of 3.6% for this group. At the 3Y‐FU, all patients in the Custom group and 26 patients (92.9%) in the Ti‐Base group were very satisfied with the treatment ( p > 0.05).

Conclusions

Within the limitations of this interim analysis, monolithic zirconia single crowns on either standardized titanium base or customized titanium abutments demonstrated stable marginal bone levels, high survival rates, high patient satisfaction, and no major technical complications during the 3Y follow‐up period. Trial Registration https://drks.de/search/en/trial/DRKS00012733

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ZirconiumTitaniumCrownsDental Prosthesis, Implant-SupportedDental AbutmentsHumansFemaleMaleMiddle AgedDental Prosthesis DesignTreatment OutcomeDental Implants, Single-ToothDental Implant-Abutment DesignBone Screws

Stichwörter der Autor:innen

clinical trialscrownsdental implantspatient satisfactionprosthodonticssurvivaltitaniumzirconium oxide

Substanzen

ZirconiumTitaniumzirconium oxide

Autor:innen und Institutionen

  • Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.
  • Department of Regenerative and Reconstructive Dental Medicine, The Institute of Science Tokyo, Tokyo, Japan.
  • Private Dental Office, Zürich, Switzerland.
  • Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea.

ORCID-Profile: Jenni Hjerppe, Stephanie Wenk, Shunsuke Fukuba, Sven Mühlemann, Ronald E Jung, Daniel S Thoma

Förderung

  • Dentsply Sirona

Zitieren

APA

Hjerppe, J., Wenk, S., Fukuba, S., Mühlemann, S., Jung, R. E., & Thoma, D. S. (2026). Randomized Controlled Clinical Trial Comparing Screw‐Retained Monolithic Zirconia Implant Crowns on Standardized Titanium Base Versus Customized Titanium Abutments– 3‐Years Data. Clinical Oral Implants Research, 37(11), 1233-1248. https://doi.org/10.1111/clr.70165

Vancouver

Hjerppe J, Wenk S, Fukuba S, Mühlemann S, Jung RE, Thoma DS. Randomized Controlled Clinical Trial Comparing Screw‐Retained Monolithic Zirconia Implant Crowns on Standardized Titanium Base Versus Customized Titanium Abutments– 3‐Years Data. Clinical Oral Implants Research. 2026;37(11):1233-1248. doi:10.1111/clr.70165

BibTeX
@article{Hjerppe2026,
  author = {Hjerppe, Jenni and Wenk, Stephanie and Fukuba, Shunsuke and Mühlemann, Sven and Jung, Ronald E and Thoma, Daniel S},
  title = {Randomized Controlled Clinical Trial Comparing Screw‐Retained Monolithic Zirconia Implant Crowns on Standardized Titanium Base Versus Customized Titanium Abutments– 3‐Years Data},
  journal = {Clinical Oral Implants Research},
  year = {2026},
  volume = {37},
  number = {11},
  pages = {1233--1248},
  doi = {10.1111/clr.70165}
}