Impact of repeated usage of two different scan bodies on the accuracy of implant position transfer: An in vitro study

Koustubh Sharadkumar Shinde, S Raghavendra Prasad, K Chethana

The Journal of Indian Prosthodontic Society · 2026

DOI: 10.4103/jips.jips_149_26 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Indian Prosthodontic Society, 2026. Verfasst von Koustubh Sharadkumar Shinde und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics and Crown and Bridge, Sri Siddhartha Academy of Higher Education, Sri Siddhartha Dental College and Hospital, Tumkur, Ka…. Hauptthemen laut MEDLINE: Polyethylene Glycols, Titanium, Ketones, Dental Implants. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To evaluate and compare the effect of repeated sterilization cycles on linear, angular, and diameter changes, and overall implant position transfer accuracy of titanium and polyetheretherketone (PEEK) scan bodies. Settings and Design: An in vitro study. Materials and Methods: An in vitro study was conducted using two maxillary acrylic models with implant analogues. Titanium and PEEK scan bodies were scanned using an intraoral scanner, with the initial scan serving as the reference. Each scan body underwent 14 steam autoclave cycles (134°C for 10 min followed by 15 min drying). Scans were exported as STL files and superimposed onto the reference dataset. Linear, angular, diameter, and root mean square (RMS) deviations were measured. Statistical Analysis Used: Data were analyzed using repeated measures analysis of variance (ANOVA). Mean differences with 95% confidence intervals were calculated, and statistical significance was set at P < 0.05.

Results

Both materials showed deviations after repeated sterilization; however, titanium scan bodies exhibited significantly lower linear, angular, and RMS deviations. PEEK demonstrated greater variability and dimensional changes.

Conclusion

Repeated sterilization affects scan body accuracy in a material-dependent manner. Titanium scan bodies showed superior dimensional stability and more consistent implant position transfer than PEEK.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Polyethylene GlycolsTitaniumKetonesDental ImplantsSterilizationBenzophenonesIn Vitro TechniquesPolyether CompoundsHumansPolymers

Stichwörter der Autor:innen

Accuracydental implantspolyetheretherketonescan bodiessterilizationtitanium

Substanzen

Polyethylene GlycolsTitaniumpolyetheretherketoneBenzophenonesKetonesPolyether CompoundsDental ImplantsPolymers

Autor:innen und Institutionen

  • Department of Prosthodontics and Crown and Bridge, Sri Siddhartha Academy of Higher Education, Sri Siddhartha Dental College and Hospital, Tumkur, Karnataka, India.

Zitieren

APA

Shinde, K. S., Raghavendra Prasad, S., & Chethana, K. (2026). Impact of repeated usage of two different scan bodies on the accuracy of implant position transfer: An in vitro study. The Journal of Indian Prosthodontic Society. https://doi.org/10.4103/jips.jips_149_26

Vancouver

Shinde KS, Raghavendra Prasad S, Chethana K. Impact of repeated usage of two different scan bodies on the accuracy of implant position transfer: An in vitro study. The Journal of Indian Prosthodontic Society. 2026. doi:10.4103/jips.jips_149_26

BibTeX
@article{Shinde2026,
  author = {Shinde, Koustubh Sharadkumar and Raghavendra Prasad, S and Chethana, K},
  title = {Impact of repeated usage of two different scan bodies on the accuracy of implant position transfer: An in vitro study},
  journal = {The Journal of Indian Prosthodontic Society},
  year = {2026},
  doi = {10.4103/jips.jips_149_26}
}
Kostenlos starten →