Influence of implant scan body material and intraoral scanner system on the accuracy of three-unit implant scans

Bahar Gürpınar, Burcu Kanat-Ertürk, Mehmet Karakuzu, Önjen Tak

The Journal of Prosthetic Dentistry · 2026-11 · 136 (5) · e30-e38

DOI: 10.1016/j.prosdent.2026.08.019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-11. Verfasst von Bahar Gürpınar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkey. Electronic address: bahargurpina…. Hauptthemen laut MEDLINE: Dental Implants, Imaging, Three-Dimensional, Computer-Aided Design. Die Arbeit nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The accuracy of implant scans may be influenced by the intraoral scanner (IOS) system and the intraoral scan body (ISB) materials. However, evidence regarding their impact remains limited. PURPOSE: The purpose of this in vitro study was to evaluate the trueness and precision of 3-unit implant scans using different ISBs and IOSs. MATERIAL AND METHODS: Two implants were placed in the right first premolar and first molar regions of a mandibular typodont model, and a 3-dimensional printed replica was fabricated. Three ISBs (Hybrid, polyetheretherketone [PEEK], titanium) were scanned using 3 IOSs: CEREC Primescan (CP), iTero Lumina (iTL), TRIOS 5 (T5). An industrial blue-light scanner (ATOS) served as the reference. Trueness was evaluated by superimposing experimental scans onto the reference scan, and precision by superimposing repeated scans of the same IOS. Three-dimensional discrepancy values were statistically analyzed with Kruskal-Wallis and pairwise comparisons with Bonferroni (α=.05). RESULTS: iTL demonstrated higher trueness and precision than other IOSs for all ISB groups (P .05). For precision, significant differences among ISBs were observed only within the iTL group (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsImaging, Three-DimensionalComputer-Aided DesignHumansBenzophenonesPolyethylene GlycolsTitaniumDental Prosthesis DesignKetonesPrinting, Three-DimensionalIn Vitro TechniquesPolyether CompoundsPolymers

Substanzen

Dental ImplantsBenzophenonespolyetheretherketonePolyethylene GlycolsTitaniumKetonesPolyether CompoundsPolymers

Autor:innen und Institutionen

  • Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkey. Electronic address: bahargurpinar@gmail.com.
  • Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey.
  • Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Mustafa Kemal University, Hatay, Turkey.
  • Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul Aydın University, Istanbul, Turkey.

Zitieren

APA

Gürpınar, B., Kanat-Ertürk, B., Karakuzu, M., & Tak, Ö. (2026). Influence of implant scan body material and intraoral scanner system on the accuracy of three-unit implant scans. The Journal of Prosthetic Dentistry, 136(5), e30-e38. https://doi.org/10.1016/j.prosdent.2026.08.019

Vancouver

Gürpınar B, Kanat-Ertürk B, Karakuzu M, Tak Ö. Influence of implant scan body material and intraoral scanner system on the accuracy of three-unit implant scans. The Journal of Prosthetic Dentistry. 2026;136(5):e30-e38. doi:10.1016/j.prosdent.2026.08.019

BibTeX
@article{Grpnar2026,
  author = {Gürpınar, Bahar and Kanat-Ertürk, Burcu and Karakuzu, Mehmet and Tak, Önjen},
  title = {Influence of implant scan body material and intraoral scanner system on the accuracy of three-unit implant scans},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  volume = {136},
  number = {5},
  pages = {e30--e38},
  doi = {10.1016/j.prosdent.2026.08.019}
}
Kostenlos starten →