EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Translating 3D-printed PEEK for orthopaedic implants: nonlinear effects of gamma sterilization on time- dependent mechanical integrity and in vivo biocompatibility

Wafa' H AlAlaween iD, Abdallah H AlAlawin iD, Mahmoud Abdallat iD, Moh'd Etoom, Anas Alwaheba iD, Mousa A Al-Abbadi iD, Manar H Hajeer iD, Abdelkarim S Aloweidi iD, Yazan Al-Zain iD

Biomedical Materials · 01.06.2026 · 21 (3) · 035029

DOI: 10.1088/1748-605x/ae76a4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Materials, online erschienen am 11.06.2026. Verfasst von Wafa' H AlAlaween und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Industrial Engineering, The University of Jordan, Amman 11942, Jordan. Hauptthemen laut MEDLINE: Biocompatible Materials, Gamma Rays, Ketones, Polyether Compounds. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Abdul Hameed Shoman Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

While fused deposition modelling (FDM) of polyether ether ketone (PEEK) has achieved regulatory acceptance and is utilized for patient-specific orthopaedic implants, the obligatory terminal sterilization via gamma irradiation raises concerns regarding polymer aging and structural degradation. This study investigates the spatiotemporal effects of gamma sterilization on the macroscopic mechanical integrity and medium-term in vivo biocompatibility of 3D-printed PEEK. Standard specimens were fabricated using a Taguchi L9 orthogonal array, manipulating key FDM parameters (layer thickness, print speed, number of shells, and raster width). To simulate a worst-case scenario of accelerated aging and free radical-induced degradation, specimens were subjected to 50 kGy of gamma irradiation and mechanically evaluated over a two-month period. In parallel, to assess clinical safety, an extensive in vivo study was conducted utilizing 81 BALB/c rats over 12 weeks. Specimens sterilized at the standard clinical dose of 25 kGy were implanted subcutaneously and compared with autoclaved controls. Mechanical testing revealed complex, nonlinear interactions between printing parameters and post-irradiation time, indicating simultaneous cross-linking and delayed oxidative chain scission mechanisms that ultimately preserved functional strength. Crucially, histological evaluation at 4, 8, and 12 weeks demonstrated excellent in vivo biocompatibility, characterized by minimal acute inflammation, rare foreign body giant cells, and the formation of a healthy, organized fibrous capsule, irrespective of the sterilization method. These findings suggest that 3D-printed PEEK maintains its structural resilience and favourable immunomodulatory profile post-gamma sterilization, successfully bridging the gap between additive manufacturing parameters and safe clinical translation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biocompatible MaterialsGamma RaysKetonesPolyether CompoundsPrinting, Three-DimensionalProstheses and ImplantsSterilizationAnimalsFemaleRatsBenzophenonesMaterials TestingMice, Inbred BALB CPolyethylene GlycolsPolymers

Stichwörter der Autor:innen

3D-printed PEEKforeign body responsefused deposition modelling (FDM)gamma sterilizationin vivo biocompatibilitypost-irradiation aging

Substanzen

BenzophenonesBiocompatible MaterialsKetonesPolyether CompoundspolyetheretherketonePolyethylene GlycolsPolymers

Autor:innen und Institutionen

  • Department of Industrial Engineering, The University of Jordan, Amman 11942, Jordan.
  • Department of Industrial Engineering, Faculty of Engineering, The Hashemite University, Zarqa, Jordan.
  • Department of Neurosurgery, School of Medicine, The University of Jordan, Amman 11942, Jordan.
  • Gamma Irradiation Facility, Jordan Atomic Energy Commission, Amman, Jordan.
  • Department of Pathology, Microbiology and Forensic Medicine, School of Medicine, The University of Jordan, Amman 11942, Jordan.
  • Department of Anesthesia and Intensive Care, School of Medicine, The University of Jordan, Amman 11942, Jordan.

ORCID-Profile: Wafa' H AlAlaween, Abdallah H AlAlawin, Mahmoud Abdallat, Anas Alwaheba, Mousa A Al-Abbadi, Manar H Hajeer, Abdelkarim S Aloweidi, Yazan Al-Zain

Förderung

  • Abdul Hameed Shoman Foundation

Zitieren

APA

AlAlaween, W. H., AlAlawin, A. H., Abdallat, M., Etoom, M., Alwaheba, A., Al-Abbadi, M. A., Hajeer, M. H., Aloweidi, A. S., & Al-Zain, Y. (2026). Translating 3D-printed PEEK for orthopaedic implants: nonlinear effects of gamma sterilization on time- dependent mechanical integrity and in vivo biocompatibility. Biomedical Materials, 21(3), 035029. https://doi.org/10.1088/1748-605x/ae76a4

Vancouver

AlAlaween WH, AlAlawin AH, Abdallat M, Etoom M, Alwaheba A, Al-Abbadi MA, et al. Translating 3D-printed PEEK for orthopaedic implants: nonlinear effects of gamma sterilization on time- dependent mechanical integrity and in vivo biocompatibility. Biomedical Materials. 2026;21(3):035029. doi:10.1088/1748-605x/ae76a4

BibTeX
@article{AlAlaween2026,
  author = {AlAlaween, Wafa' H and AlAlawin, Abdallah H and Abdallat, Mahmoud and Etoom, Moh'd and Alwaheba, Anas and Al-Abbadi, Mousa A and Hajeer, Manar H and Aloweidi, Abdelkarim S and Al-Zain, Yazan},
  title = {Translating 3D-printed PEEK for orthopaedic implants: nonlinear effects of gamma sterilization on time- dependent mechanical integrity and in vivo biocompatibility},
  journal = {Biomedical Materials},
  year = {2026},
  volume = {21},
  number = {3},
  pages = {035029},
  doi = {10.1088/1748-605x/ae76a4}
}
Kostenlos starten →