Robot-assisted cervical pedicle screw placement using a novel hybrid dilator technique: A clinical series of 565 screws
Journal of Craniovertebral Junction and Spine · 2025-07 · 16 (3) · 301-306
DOI: 10.4103/jcvjs.jcvjs_115_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Craniovertebral Junction and Spine, online erschienen am 18.09.2025. Verfasst von Abhishek Soni und 3 weiteren Autor:innen. Beteiligte Einrichtung: Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Centre, Manipal Hospital, Bangalore, Karnataka, India. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Background
Cervical pedicle screws provide superior biomechanical fixation with pullout strength four times greater than lateral mass screws, but placement is technically demanding with traditional malposition rates of 6.7%–31.6%. Robotic-assisted spine surgery has demonstrated success in thoracolumbar applications, but cervical translation has been hindered by the lack of cervical-specific instrumentation requiring expensive custom instruments.
Methods
We developed a hybrid technique combining robotic guidance with standard cervical instrumentation using minimally invasive surgery dilators as an interface. Sixty-five consecutive patients underwent robot-assisted cervical pedicle screw placement with 565 screws across C2–C7 levels using MazorX Stealth robotic system with O-arm navigation. Accuracy was assessed using Gertzbein-Robbins and Neo classification systems with 3–6-month follow-up for complications.
Results
The technique achieved 98.76% clinically acceptable accuracy (Gertzbein-Robbins Grade A + B) with 1.24% breach rate. Perfect placement (Grade A) occurred in 95.22% of screws. Vertebral artery protection was excellent with 99.65% showing no foramen breach. Major complications occurred in 1.5% of patients (single vertebral artery injury), with 7.7% experiencing transient C5 weakness that resolved completely. No patients required revision surgery.
Conclusions
This hybrid technique addresses instrument compatibility barriers in robotic cervical spine surgery by eliminating dependence on custom instruments while maintaining robotic accuracy. The technique demonstrates superior outcomes compared to traditional approaches and facilitates broader robotic cervical surgery adoption. Multi-center validation studies are needed to establish the generalizability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Centre, Manipal Hospital, Bangalore, Karnataka, India.
- Department of Orthopaedics, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
Zitieren
APA
Soni, A., Vidyadhara, S., Kanhangad, M. P., & Balamurugan, T. (2025). Robot-assisted cervical pedicle screw placement using a novel hybrid dilator technique: A clinical series of 565 screws. Journal of Craniovertebral Junction and Spine, 16(3), 301-306. https://doi.org/10.4103/jcvjs.jcvjs_115_25
Vancouver
Soni A, Vidyadhara S, Kanhangad MP, Balamurugan T. Robot-assisted cervical pedicle screw placement using a novel hybrid dilator technique: A clinical series of 565 screws. Journal of Craniovertebral Junction and Spine. 2025;16(3):301-306. doi:10.4103/jcvjs.jcvjs_115_25
BibTeX
@article{Soni2025,
author = {Soni, Abhishek and Vidyadhara, S and Kanhangad, Madhava Pai and Balamurugan, T},
title = {Robot-assisted cervical pedicle screw placement using a novel hybrid dilator technique: A clinical series of 565 screws},
journal = {Journal of Craniovertebral Junction and Spine},
year = {2025},
volume = {16},
number = {3},
pages = {301--306},
doi = {10.4103/jcvjs.jcvjs_115_25}
}
EUVIMED