Accuracy and safety of robot-assisted pedicle screw placement in the management of cervical spine disorders
Journal of Robotic Surgery · 02.04.2026 · 20 (1)
DOI: 10.1007/s11701-026-03358-w ↗Kurz gefasst
Metaanalyse in der Zeitschrift Journal of Robotic Surgery, online erschienen am 02.04.2026. Verfasst von Xiangyang Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: The First Clinical Medical College of Ningxia Medical University, Ningxia Hui Autonomous Region, Yinchuan, 750004, Ningxia, PR China. Hauptthemen laut MEDLINE: Pedicle Screws, Robotic Surgical Procedures, Cervical Vertebrae, Spinal Diseases. Die Arbeit nennt 29 Literaturangaben. Gefördert von: University-Level Natural Science Project (Young Scholars Program), North Sichuan Medical College, Nanchong Philosophy and Social Sciences Research Planning Project.
Abstract (Originalsprache)
To systematically evaluate and compare the accuracy and safety of robot-assisted versus conventional freehand pedicle screw placement in the surgical management of cervical spine disorders. A comprehensive literature search was conducted to identify published comparative studies. Eligible studies were selected according to predefined criteria. Relevant data were extracted, and methodological quality was assessed. Pooled effect estimates were calculated using meta-analytic techniques to compare perioperative parameters, screw placement accuracy, and clinical outcomes between the two surgical approaches. Compared with conventional techniques, robot-assisted pedicle screw placement was associated with a longer overall operative time (MD = 37.52 min, 95% CI 17.69–57.34) but a shorter insertion time per screw (MD = − 1.50 min, 95% CI − 2.00 to − 1.00). In addition, robotic assistance was associated with reduced intraoperative blood loss (MD = − 49.82 mL, 95% CI − 91.71 to − 7.93) and shorter postoperative hospital stay (MD = − 1.31 days, 95% CI − 2.26 to − 0.37). Regarding screw placement accuracy, the robot-assisted group demonstrated a significantly higher proportion of GRAD grade A + B screws (OR = 3.89, 95% CI 1.77–8.53) and Grade 0 screws (OR = 1.51, 95% CI 1.08–2.12). A small but statistically significant reduction in Neck Disability Index scores at 3 months was also observed (MD = − 0.69, 95% CI − 1.18 to − 0.21). Current evidence suggests that robot-assisted pedicle screw placement offers advantages in terms of screw placement accuracy, postoperative functional recovery, and reduced length of hospital stay in patients with cervical spine disorders. The choice of surgical technique should be individualized based on patient characteristics, availability of robotic systems, and surgeon expertise.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The First Clinical Medical College of Ningxia Medical University, Ningxia Hui Autonomous Region, Yinchuan, 750004, Ningxia, PR China.
- Department of Pain, Beijing Anzhen Nanchong Hospital of Capital Medical University & Nanchong Central Hospital, Nanchong, China.
- School of Basic Medicine and Forensic Medicine, North Sichuan Medical College, No.234 Fujiang Road, Nanchong, 637000, Sichuan, China.
- The First Clinical Medical College of Ningxia Medical University, Ningxia Hui Autonomous Region, Yinchuan, 750004, Ningxia, PR China. 1428421664@qq.com.
Förderung
- University-Level Natural Science Project (Young Scholars Program), North Sichuan Medical College
- Nanchong Philosophy and Social Sciences Research Planning Project
Zitieren
APA
Li, X., Shen, G., Gao, Z., Wang, R., & Dai, Y. (2026). Accuracy and safety of robot-assisted pedicle screw placement in the management of cervical spine disorders. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-03358-w
Vancouver
Li X, Shen G, Gao Z, Wang R, Dai Y. Accuracy and safety of robot-assisted pedicle screw placement in the management of cervical spine disorders. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-03358-w
BibTeX
@article{Li2026,
author = {Li, Xiangyang and Shen, Guohang and Gao, Zhenguo and Wang, Ruoyan and Dai, Yupei},
title = {Accuracy and safety of robot-assisted pedicle screw placement in the management of cervical spine disorders},
journal = {Journal of Robotic Surgery},
year = {2026},
volume = {20},
number = {1},
doi = {10.1007/s11701-026-03358-w}
}
EUVIMED