EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access · CC BY 4.0

A Retrospective Cohort Study Comparing Robot-Assisted and Conventional Fluoroscopy-Guided Pedicle Screw Placement

Hassan Seif, Emanuele Maragno iD, Marco Gallus, Szabolcs Szeöke, Michael Schwake iD

Journal of Clinical Medicine · 26.09.2025 · 14 (19) · 6831

DOI: 10.3390/jcm14196831 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Journal of Clinical Medicine, online erschienen am 26.09.2025. Verfasst von Hassan Seif und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Spine Surgery, Brüder St. Josef Hospital, D-33098 Paderborn, Germany. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Pedicle screw placement is crucial for restoring stability. Emerging robot-assisted technologies may offer enhanced precision and reduced radiation exposure. This study aimed to compare the accuracy and clinical outcomes of robot-assisted versus conventional fluoroscopy-guided pedicle screw placements.

Methods

This retrospective cohort study included 218 patients undergoing pedicle screw placement at a single spine center between 2019 and 2023. Of these, 105 patients underwent robot-assisted surgery using the Mazor X™ Stealth Edition (Medtronic, Minneapolis, MN, USA), and 113 underwent conventional fluoroscopy-guided surgery. The primary outcome was screw placement accuracy (Grade 0 = optimal, Grades 1–3 = suboptimal, according to the Gertzbein–Robbins classification). Secondary outcomes included estimated blood loss (EBL), radiation exposure, length of hospital stay (LOS), clinical outcome according to the Macnab classification, postoperative pain, and adverse events.

Results

Robot-assisted surgery demonstrated significantly higher accuracy in screw placement, with 93.33% achieving Grade 0 accuracy versus 78.76% in the conventional group (p = 0.002). This corresponded to an odds ratio (OR) of 3.78 (95% CI: 1.55–9.19, p = 0.003). The number needed to treat (NNT) to achieve one additional optimal screw placement was 6.9. Robot-assisted surgery demonstrated significantly higher accuracy in screw placement. Moreover, robot-assisted procedures were associated with reduced estimated blood loss (EBL), shorter length of stay (LOS), and lower radiation exposure times; patient-reported outcomes (VAS and Macnab) were also improved (OR = 3.34, 95% CI: 1.89–5.91). Duration of surgery, adverse events, and revision rates were comparable between the two groups.

Conclusions

This study supports the clinical benefits of robot-assisted pedicle screw placement, particularly in achieving higher accuracy and reducing EBL and LOS. Future research should explore long-term outcomes, cost-effectiveness, and the generalizability of these results to a broader patient population.

Schlagwörter

Stichwörter der Autor:innen

Roboticsnavigationspinal fusion

Autor:innen und Institutionen

  • Department of Spine Surgery, Brüder St. Josef Hospital, D-33098 Paderborn, Germany.
  • Department of Neurosurgery, Klinikum Dortmund, D-44145 Dortmund, Germany.
  • Faculty of Health, University Witten/Herdecke, D-58455 Witten, Germany.
  • Department of Neurosurgery, University Hospital Münster, D-48149 Münster, Germany.
  • Department of Neurosurgery, University of California San Francisco, San Francisco, CA 94143, USA.

ORCID-Profile: Emanuele Maragno, Michael Schwake

Zitieren

APA

Seif, H., Maragno, E., Gallus, M., Szeöke, S., & Schwake, M. (2025). A Retrospective Cohort Study Comparing Robot-Assisted and Conventional Fluoroscopy-Guided Pedicle Screw Placement. Journal of Clinical Medicine, 14(19), 6831. https://doi.org/10.3390/jcm14196831

Vancouver

Seif H, Maragno E, Gallus M, Szeöke S, Schwake M. A Retrospective Cohort Study Comparing Robot-Assisted and Conventional Fluoroscopy-Guided Pedicle Screw Placement. Journal of Clinical Medicine. 2025;14(19):6831. doi:10.3390/jcm14196831

BibTeX
@article{Seif2025,
  author = {Seif, Hassan and Maragno, Emanuele and Gallus, Marco and Szeöke, Szabolcs and Schwake, Michael},
  title = {A Retrospective Cohort Study Comparing Robot-Assisted and Conventional Fluoroscopy-Guided Pedicle Screw Placement},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {19},
  pages = {6831},
  doi = {10.3390/jcm14196831}
}
Kostenlos starten →