EUVIMEDEUVIMED entdecken
Crossref

Evaluation of the effect of moisture and saliva on the shear bond strength of brackets bonded with conventional bonding system and moisture insensitive primer: An in vitro study

IGirish Kumar, A Bhagyalakshmi, BM Shivalinga, N Raghunath

International Journal of Orthodontic Rehabilitation · 2018 · 9 (4) · 145

DOI: 10.4103/ijor.ijor_44_17 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Orthodontic Rehabilitation, 2018. Verfasst von IGirish Kumar und 3 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Bonding of orthodontic attachments with acid etching is the most commonly used orthodontic procedure. However, there are certain limitations with acid etching procedure like/moisture contamination, etching time, the concentration of adhesive, etc., Moisture insensitive primers (MIPs) were introduced to overcome these limitations.

Objectives

The aim of this study is to compare the shear bond strength of orthodontic brackets bonded with a MIP (Transbond MIP, 3M Unitek) against a conventional primer (Transbond XT, 3M Unitek) when contaminated with saliva – in vitro study.Methodology: Sixty maxillary premolars extracted for orthodontic purpose or due to periodontal involvement with sound buccal surfaces were collected, cleaned thoroughly, and stored in 0.1% (wt/vol) thymol at room temperature for 2 weeks. Following materials were used: Transbond XT Light cure adhesive (3M unitek), Transbond XT primer (3m unitek), Transbond MIP primer (3M unitek), and Metal brackets (3M unitek). A commercially available artificial saliva (AQWET, CIPLA) was used for contamination purpose. Ivoclarbluephase N LED light curing unit were used for curing purpose.

Results

Mean bond strength was well above the clinically acceptable bond strength values indicating the use of these hydrophilic bonding materials in contaminated environments (8.5 Mpa for Transbond XT and 9.25 Mpa for Transbond MIP). On comparison of bond strengths of MIP and XT when contaminated with saliva, statistically significant values were obtained with contamination with saliva after primer application. There was a statistically significant increase in the bond strength after primer application (P = 0.233) and before and after primer application (P = 0.027*). Transbond MIP can be used to achieve adequate bond strength in saliva contaminated condition.

Conclusion

Under dry condition, the shear bond strength of conventional primer (TRANSBOND XT) was significantly increased when compared to MIP. Under wet conditions MIP (TRANSBOND MIP) showed the highest shear bond strength and hence can be considered as a material of choice in wet conditions.

Zitieren

APA

Kumar, I., Bhagyalakshmi, A., Shivalinga, B., & Raghunath, N. (2018). Evaluation of the effect of moisture and saliva on the shear bond strength of brackets bonded with conventional bonding system and moisture insensitive primer: An in vitro study. International Journal of Orthodontic Rehabilitation, 9(4), 145. https://doi.org/10.4103/ijor.ijor_44_17

Vancouver

Kumar I, Bhagyalakshmi A, Shivalinga B, Raghunath N. Evaluation of the effect of moisture and saliva on the shear bond strength of brackets bonded with conventional bonding system and moisture insensitive primer: An in vitro study. International Journal of Orthodontic Rehabilitation. 2018;9(4):145. doi:10.4103/ijor.ijor_44_17

BibTeX
@article{Kumar2018,
  author = {Kumar, IGirish and Bhagyalakshmi, A and Shivalinga, BM and Raghunath, N},
  title = {Evaluation of the effect of moisture and saliva on the shear bond strength of brackets bonded with conventional bonding system and moisture insensitive primer: An in vitro study},
  journal = {International Journal of Orthodontic Rehabilitation},
  year = {2018},
  volume = {9},
  number = {4},
  pages = {145},
  doi = {10.4103/ijor.ijor_44_17}
}
Kostenlos starten →