EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Comparative Evaluation of Shear Bond Strength of Orthodontic Metal Bracket Bonded with the Conventional Adhesive System and Moisture Insensitive Primer System on a Tooth Surface Which has Undergone Bleaching with 35% Hydrogen Peroxide – An In Vitro Study

Praveen Roy, K K Manjusha, A Nishad, Ashitha Aravindan, J K Krishnajith, K A Jameema

Journal of Pharmacy and Bioallied Sciences · 2024-12 · 16 (Suppl 5) · S4613-S4617

DOI: 10.4103/jpbs.jpbs_963_24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pharmacy and Bioallied Sciences, online erschienen am 30.01.2025. Verfasst von Praveen Roy und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics and Dentofacial Orthopaedics, Noorul Islam College of Dental Sciences, Neyyattinkara, Trivandrum, Kerala, India. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A BSTRACT Background and Objectives: Today, orthodontic bracket bonding on the tooth surface is a vital phase in any orthodontic therapy as strong tooth-bracket bonding is essential for success and efficiency. Tooth whitening is popular due to tooth discolouration and patient need for esthetic changes. This in vitro study compared the shear bond strength (SBS) and adhesive remnant index (ARI) of brackets bonded with a conventional and moisture-insensitive primer system on tooth surfaces bleached with 35% hydrogen peroxide in dry and moisture conditions.

Methods

Fifty-six healthy humans with extracted maxillary first premolars were cleaned using a periodontal curette, rinsed, treated with 35% hydrogen peroxide, and kept in a 0.1% thymol aqueous solution at room temperature. These teeth were embedded in orthodontic acrylic resin in four groups: the conventional primer system in dry conditions, the conventional primer system in moist conditions using artificial saliva, the moisture insensitive primer system in dry conditions, and the moisture insensitive primer system in moist conditions. After bonding metal brackets to tooth surfaces bleached with 35% hydrogen peroxide, universal testing machine and a stereomicroscope were used to calculate SBS and ARI. Results and Discussion: SBS and ARI values were the lowest in the conventional primer system in moist conditions, with statistically significant differences between groups. The study’s findings match earlier research. In vivo research should evaluate SBS and ARI to support in vitro findings.

Conclusion

In the current study, moisture was found to be a factor affecting SBS and ARI. The moisture-insensitive bonding system was found to be resistant to effects of moisture compared with the conventional system.

Schlagwörter

Stichwörter der Autor:innen

Adhesive remnant indexconventional primer systemmoisture insensitive primer systemshear bond strength

Autor:innen und Institutionen

  • Department of Orthodontics and Dentofacial Orthopaedics, Noorul Islam College of Dental Sciences, Neyyattinkara, Trivandrum, Kerala, India.

Zitieren

APA

Roy, P., Manjusha, K. K., Nishad, A., Aravindan, A., Krishnajith, J. K., & Jameema, K. A. (2024). Comparative Evaluation of Shear Bond Strength of Orthodontic Metal Bracket Bonded with the Conventional Adhesive System and Moisture Insensitive Primer System on a Tooth Surface Which has Undergone Bleaching with 35% Hydrogen Peroxide – An In Vitro Study. Journal of Pharmacy and Bioallied Sciences, 16(Suppl 5), S4613-S4617. https://doi.org/10.4103/jpbs.jpbs_963_24

Vancouver

Roy P, Manjusha KK, Nishad A, Aravindan A, Krishnajith JK, Jameema KA. Comparative Evaluation of Shear Bond Strength of Orthodontic Metal Bracket Bonded with the Conventional Adhesive System and Moisture Insensitive Primer System on a Tooth Surface Which has Undergone Bleaching with 35% Hydrogen Peroxide – An In Vitro Study. Journal of Pharmacy and Bioallied Sciences. 2024;16(Suppl 5):S4613-S4617. doi:10.4103/jpbs.jpbs_963_24

BibTeX
@article{Roy2024,
  author = {Roy, Praveen and Manjusha, K K and Nishad, A and Aravindan, Ashitha and Krishnajith, J K and Jameema, K A},
  title = {Comparative Evaluation of Shear Bond Strength of Orthodontic Metal Bracket Bonded with the Conventional Adhesive System and Moisture Insensitive Primer System on a Tooth Surface Which has Undergone Bleaching with 35% Hydrogen Peroxide – An In Vitro Study},
  journal = {Journal of Pharmacy and Bioallied Sciences},
  year = {2024},
  volume = {16},
  number = {Suppl 5},
  pages = {S4613--S4617},
  doi = {10.4103/jpbs.jpbs_963_24}
}
Kostenlos starten →