Evaluation of Shear Bond Strength of Conventional versus Moisture-Insensitive Orthodontic Adhesives Following Acute Thermocycling: An In Vitro Study
International Journal of Drug Delivery Technology · 29.05.2026 · 16 (35s)
DOI: 10.25258/ijddt.16.35s.83 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 29.05.2026. Verfasst von Soumya Mishra und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Objective
To evaluate and compare the shear bond strength (SBS) and adhesive remnant index (ARI) of conventional and moisture-insensitive orthodontic adhesives after acute thermocycling simulation. Materials and Methods: Sixty extracted human premolars were randomly divided into two groups (n=30 each): Group 1 bonded with conventional adhesive (Transbond XT); Group 2 bonded with moisture-insensitive adhesive (Transbond MIP). All samples underwent 500 thermocycles (5°C-55°C, 30-second dwell time). SBS was measured using a Universal Testing Machine, and ARI scores were assessed under stereomicroscope at 10× magnification. Statistical analysis included independent t-test and Chi-square test (α=0.05).
Results
Mean SBS fo r Transbond XT was 12.34±2.67 MPa versus 13.89±2.41 MPa for Transbond MIP (p=0.021). Both groups showed predominantly cohesive failures with no significant difference in ARI distribution (p=0.312).
Conclusions
Moisture-insensitive adhesive exhibited significantly higher shear bond strength following acute thermocycling while maintaining clinically acceptable bond strengths (>6 MPa). Both adhesives demonstrated favorable failure patterns, suggesting moisture-insensitive systems may provide superior performance during the critical initial bonding period.
Zitieren
APA
Mishra, S., S, K., Ankita, P., Pani, S., Dubey, A., & Saha, S. C. (2026). Evaluation of Shear Bond Strength of Conventional versus Moisture-Insensitive Orthodontic Adhesives Following Acute Thermocycling: An In Vitro Study. International Journal of Drug Delivery Technology, 16(35s). https://doi.org/10.25258/ijddt.16.35s.83
Vancouver
Mishra S, S K, Ankita P, Pani S, Dubey A, Saha SC. Evaluation of Shear Bond Strength of Conventional versus Moisture-Insensitive Orthodontic Adhesives Following Acute Thermocycling: An In Vitro Study. International Journal of Drug Delivery Technology. 2026;16(35s). doi:10.25258/ijddt.16.35s.83
BibTeX
@article{Mishra2026,
author = {Mishra, Soumya and S, Krishna and Ankita, P.V.S. and Pani, Saibalini and Dubey, Abhishek and Saha, Shubhra Chandan},
title = {Evaluation of Shear Bond Strength of Conventional versus Moisture-Insensitive Orthodontic Adhesives Following Acute Thermocycling: An In Vitro Study},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {35s},
doi = {10.25258/ijddt.16.35s.83}
}