Clinical utility, feasibility of home tonometry using iCare HOME by glaucoma patients

Sujatha V Kadambi, M Aishwarya, C Leelavathy, Ronnie George, Shantha Balekudaru, Vijaya Lingam, Mani Baskaran

Indian Journal of Ophthalmology · 2023-07 · 71 (7) · 2727-2732

DOI: 10.4103/ijo.ijo_147_23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 05.07.2023. Verfasst von Sujatha V Kadambi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Smt Jadhavbai Nathmal Singhvee Glaucoma Services, Chennai, Tamil Nadu, India. Hauptthemen laut MEDLINE: Glaucoma. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To determine agreement between diurnal variation testing (DVT) of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT) and iCare HOME (IH) by an optometrist (OP) and home monitoring by participants (PT).

Methods

Patients (18–80 years) with glaucoma and suspects were enrolled. IH IOP and GAT were taken by an OP at 2 h intervals from 8 AM to 4 PM on Day 1 and PT between 6 AM and 9 PM, for the next 2 days. IOP, date, and time were viewed via iCare LINK software.

Results

In total, 72.9% (51/70) PT trained were able to take reliable readings. One hundred two eyes (51 patients, age 53 ± 16 yrs) were analyzed. Correlation between optometrist (OP) and participants (PT) was strong and positive {IH OP-IH PT- r = 0.90, p-0.0001;IH PT-GAT- r = 0.79, p-0.0001}. Agreement by Bland Altman plots was limited {IH OP-IH PT mean 0.1 mmHg (95% LOA -5.3 to 5.5), IH PT-GAT 2.2 mmHg (-5.7 to 10.1)}. Intraclass correlation coefficient for IH OP-IH PT was 1.18 (95% CI 1.37-1.09). Intradevice {0.95 (95% CI 0.94-0.97)} and interrater repeatability {0.91 (0.79–0.96)} were good. 37% of eyes had a synchronous peak on GAT and IH during the day DVT.

Conclusion

Home tonometry by iCare HOME is easy, feasible, but due to limited agreement cannot substitute GAT DVT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlaucomaHumansAdultMiddle AgedAgedFeasibility StudiesReproducibility of ResultsTonometry, OcularIntraocular Pressure

Stichwörter der Autor:innen

Home tonometryglaucomaiCare HOME

Autor:innen und Institutionen

  • Smt Jadhavbai Nathmal Singhvee Glaucoma Services, Chennai, Tamil Nadu, India.
  • Department of Optometry, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India.

Zitieren

APA

Kadambi, S. V., Aishwarya, M., Leelavathy, C., George, R., Balekudaru, S., Lingam, V., & Baskaran, M. (2023). Clinical utility, feasibility of home tonometry using iCare HOME by glaucoma patients. Indian Journal of Ophthalmology, 71(7), 2727-2732. https://doi.org/10.4103/ijo.ijo_147_23

Vancouver

Kadambi SV, Aishwarya M, Leelavathy C, George R, Balekudaru S, Lingam V, et al. Clinical utility, feasibility of home tonometry using iCare HOME by glaucoma patients. Indian Journal of Ophthalmology. 2023;71(7):2727-2732. doi:10.4103/ijo.ijo_147_23

BibTeX
@article{Kadambi2023,
  author = {Kadambi, Sujatha V and Aishwarya, M and Leelavathy, C and George, Ronnie and Balekudaru, Shantha and Lingam, Vijaya and Baskaran, Mani},
  title = {Clinical utility, feasibility of home tonometry using iCare HOME by glaucoma patients},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  volume = {71},
  number = {7},
  pages = {2727--2732},
  doi = {10.4103/ijo.ijo_147_23}
}