Clinical utility, feasibility of home tonometry using iCare HOME by glaucoma patients
Indian Journal of Ophthalmology · 2023-07 · 71 (7) · 2727-2732
DOI: 10.4103/ijo.ijo_147_23 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 05.07.2023. Verfasst von Sujatha V Kadambi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Smt Jadhavbai Nathmal Singhvee Glaucoma Services, Chennai, Tamil Nadu, India. Hauptthemen laut MEDLINE: Glaucoma. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Purpose
To determine agreement between diurnal variation testing (DVT) of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT) and iCare HOME (IH) by an optometrist (OP) and home monitoring by participants (PT).
Methods
Patients (18–80 years) with glaucoma and suspects were enrolled. IH IOP and GAT were taken by an OP at 2 h intervals from 8 AM to 4 PM on Day 1 and PT between 6 AM and 9 PM, for the next 2 days. IOP, date, and time were viewed via iCare LINK software.
Results
In total, 72.9% (51/70) PT trained were able to take reliable readings. One hundred two eyes (51 patients, age 53 ± 16 yrs) were analyzed. Correlation between optometrist (OP) and participants (PT) was strong and positive {IH OP-IH PT- r = 0.90, p-0.0001;IH PT-GAT- r = 0.79, p-0.0001}. Agreement by Bland Altman plots was limited {IH OP-IH PT mean 0.1 mmHg (95% LOA -5.3 to 5.5), IH PT-GAT 2.2 mmHg (-5.7 to 10.1)}. Intraclass correlation coefficient for IH OP-IH PT was 1.18 (95% CI 1.37-1.09). Intradevice {0.95 (95% CI 0.94-0.97)} and interrater repeatability {0.91 (0.79–0.96)} were good. 37% of eyes had a synchronous peak on GAT and IH during the day DVT.
Conclusion
Home tonometry by iCare HOME is easy, feasible, but due to limited agreement cannot substitute GAT DVT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Smt Jadhavbai Nathmal Singhvee Glaucoma Services, Chennai, Tamil Nadu, India.
- Department of Optometry, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India.
Zitieren
APA
Kadambi, S. V., Aishwarya, M., Leelavathy, C., George, R., Balekudaru, S., Lingam, V., & Baskaran, M. (2023). Clinical utility, feasibility of home tonometry using iCare HOME by glaucoma patients. Indian Journal of Ophthalmology, 71(7), 2727-2732. https://doi.org/10.4103/ijo.ijo_147_23
Vancouver
Kadambi SV, Aishwarya M, Leelavathy C, George R, Balekudaru S, Lingam V, et al. Clinical utility, feasibility of home tonometry using iCare HOME by glaucoma patients. Indian Journal of Ophthalmology. 2023;71(7):2727-2732. doi:10.4103/ijo.ijo_147_23
BibTeX
@article{Kadambi2023,
author = {Kadambi, Sujatha V and Aishwarya, M and Leelavathy, C and George, Ronnie and Balekudaru, Shantha and Lingam, Vijaya and Baskaran, Mani},
title = {Clinical utility, feasibility of home tonometry using iCare HOME by glaucoma patients},
journal = {Indian Journal of Ophthalmology},
year = {2023},
volume = {71},
number = {7},
pages = {2727--2732},
doi = {10.4103/ijo.ijo_147_23}
}