Accuracy of Cone-beam Computed Tomography in Determining Implant Length and Diameter: A Comparative Clinical Evaluation
Annals of African Medicine · 16.11.2026
DOI: 10.4103/aam.aam_658_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of African Medicine, online erschienen am 16.11.2026. Verfasst von Yadlapalli Sravanthi und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Accurate preoperative assessment of implant dimensions is a critical determinant of success in dental implant therapy. Precise estimation of implant length and diameter helps avoid complications such as cortical plate perforation, inferior alveolar nerve injury, and inadequate primary stability. Cone-beam computed tomography (CBCT) has become an important imaging modality in implant dentistry because it provides three-dimensional visualization with relatively low radiation exposure compared to conventional computed tomography.
Aim
The study aimed to evaluate the accuracy of CBCT in determining implant length and diameter by comparing radiographic measurements with actual implant dimensions used during surgery. Study Design and Setting: This was a prospective, comparative clinical study conducted in a dental teaching hospital. Subjects and Methods: Patients requiring dental implant placement were included in the study. Preoperative CBCT scans were obtained, and measurements of proposed implant length and diameter were recorded using dedicated CBCT software. During implant placement, the actual implant length and diameter used were documented. Radiographic measurements obtained from CBCT were then compared with the clinical implant dimensions.
Results
CBCT measurements showed a high degree of agreement with the actual implant length and diameter used during surgery. Minor discrepancies were observed, but these differences were within clinically acceptable limits. CBCT demonstrated high accuracy in preoperative assessment of implant dimensions.
Conclusion
CBCT is a reliable and accurate imaging modality for determining implant length and diameter. Its use in preoperative planning can enhance surgical safety and improve the clinical outcomes in dental implant therapy.
Zitieren
APA
Sravanthi, Y., & Kumar, T. R. (2026). Accuracy of Cone-beam Computed Tomography in Determining Implant Length and Diameter: A Comparative Clinical Evaluation. Annals of African Medicine. https://doi.org/10.4103/aam.aam_658_26
Vancouver
Sravanthi Y, Kumar TR. Accuracy of Cone-beam Computed Tomography in Determining Implant Length and Diameter: A Comparative Clinical Evaluation. Annals of African Medicine. 2026. doi:10.4103/aam.aam_658_26
BibTeX
@article{Sravanthi2026,
author = {Sravanthi, Yadlapalli and Kumar, Tripuraneni Rajesh},
title = {Accuracy of Cone-beam Computed Tomography in Determining Implant Length and Diameter: A Comparative Clinical Evaluation},
journal = {Annals of African Medicine},
year = {2026},
doi = {10.4103/aam.aam_658_26}
}
EUVIMED