Comparative evaluation of immediately loaded implants in both immediate and delayed implant placement with cone-beam computed tomography analysis
Journal of Indian Society of Periodontology · 2025-01 · 29 (1) · 14-19
DOI: 10.4103/jisp.jisp_445_23 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Indian Society of Periodontology, online erschienen am 10.06.2025. Verfasst von Vedhavani Muthaiyan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontics and Implant Dentistry, Tamil Nadu Government Dental College and Hospital, Chennai, Tamil Nadu, India. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Background
Conventionally, dental implants were placed several months after tooth extraction. Immediate implants were placed on the same day of extraction along with the conservation of the crestal bone. Immediate loading of implant facilitates immediate prosthetic reconstruction within 48 h of implant placement. In this study, both immediate and delayed implants were loaded immediately and their peri-implant bone loss, implant stability, and the soft-tissue outcomes around the implant were evaluated. Materials and Methods: Fourteen patients were included in this study, of which seven patients were under Group A (delayed) and seven patients were under Group B (immediate). The clinical evaluation was done at baseline, 3 months, and 6 months which includes plaque scores, bleeding on probing, and probing depth. Implant stability was tested by resonance frequency analyzer (implant stability quotient), and radiological evaluation of crestal bone loss was done by cone-beam computed tomography preoperatively and after 6 months.
Results
In this study, there was no statistically significant difference ( P > 0.05) in the clinical parameters (plaque index, bleeding on probing, and probing depth) and radiological outcomes within the groups at baseline, 3 months, and 6 months. The implant stability quotient and crestal bone loss between Groups A and B showed a statistically significant difference at baseline and 6 months, wherein there were higher implant stability and decreased crestal bone loss in Group A when compared to Group B.
Conclusion
Delayed implants with immediate loading were superior to immediate implants with immediate loading.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Periodontics and Implant Dentistry, Tamil Nadu Government Dental College and Hospital, Chennai, Tamil Nadu, India.
Zitieren
APA
Muthaiyan, V., Krishnamurthi, M., Arunachalam, M., Mujeeb, S. A., & Reddy, C. H. B. (2025). Comparative evaluation of immediately loaded implants in both immediate and delayed implant placement with cone-beam computed tomography analysis. Journal of Indian Society of Periodontology, 29(1), 14-19. https://doi.org/10.4103/jisp.jisp_445_23
Vancouver
Muthaiyan V, Krishnamurthi M, Arunachalam M, Mujeeb SA, Reddy CHB. Comparative evaluation of immediately loaded implants in both immediate and delayed implant placement with cone-beam computed tomography analysis. Journal of Indian Society of Periodontology. 2025;29(1):14-19. doi:10.4103/jisp.jisp_445_23
BibTeX
@article{Muthaiyan2025,
author = {Muthaiyan, Vedhavani and Krishnamurthi, Malathi and Arunachalam, Muthukumaraswamy and Mujeeb, Shabbir Ahamed and Reddy, Chagnoor Hima Bindu},
title = {Comparative evaluation of immediately loaded implants in both immediate and delayed implant placement with cone-beam computed tomography analysis},
journal = {Journal of Indian Society of Periodontology},
year = {2025},
volume = {29},
number = {1},
pages = {14--19},
doi = {10.4103/jisp.jisp_445_23}
}
EUVIMED