EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Mapping optimal orthodontic implant sites in the palate using cone-beam computed tomography

Zhengxian Zhu, Lin Zhong, Yicheng Zhao, Xiaoting Wang, Wenhao Qian, Niansong Ye

Frontiers in Oral Health · 02.10.2024 · 5

DOI: 10.3389/froh.2024.1453665 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Oral Health, online erschienen am 02.10.2024. Verfasst von Zhengxian Zhu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Shanghai Xuhui District Dental Center, Shanghai, China. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To measure the palatal soft tissue thickness and cortical bone density to determine safe regions for the placement of orthodontic mini-implants and to examine the influence of sex and age on soft tissue thickness and cortical bone density. Materials and methods Cone-beam computed tomography images of 42 patients (22 males and 20 females), including 21 adults and 21 adolescents, were examined in this study. The palatal soft tissue thickness and cortical bone density were measured at the coronal planes between the premolars (P4–5), between the second premolars and first molars (P5–6), and between the first molars and second molars (P6–7).

Results

The thickness of the soft tissue revealed similar coronal planes, but the bone density varied. The mean thickness was 3.8 mm at 0°–60° and 1.5 mm at 60°–90°. P4–5 had the highest bone density (>600 HU), decreasing toward P6–7 (<600 HU). Bone density decreased from 90° to 0° coronally, whereas the soft tissue thickness increased. Age, sex, and their interaction affected bone and soft tissues.

Conclusions

In general, areas with a high bone density tended to have thin soft tissue coronally, thus the preferred implant site tends to be more anterior to the P4–5 plane and closer to 60°–90°. Considering individual variances, mapping of the recommended regions for palatal mini-implants is suggested.

Schlagwörter

Stichwörter der Autor:innen

cone-beam CTcortical densitymini-implant anchorageorthodontic mini-implantspalatal thickness

Autor:innen und Institutionen

  • Department of Orthodontics, Shanghai Xuhui District Dental Center, Shanghai, China.
  • Department of Stomatology, Shanghai Jing'an District Central Hospital, Shanghai, China.
  • Department of Oral Prothodontics, Stomatological Hospital of Tianjin Medical University, Tianjin, China.
  • Department of Implantology, Shanghai Xuhui District Dental Center, Shanghai, China.
  • Department of Orthodontics, Shanghai Hua Guang Private Practice, Shanghai, China.

Zitieren

APA

Zhu, Z., Zhong, L., Zhao, Y., Wang, X., Qian, W., & Ye, N. (2024). Mapping optimal orthodontic implant sites in the palate using cone-beam computed tomography. Frontiers in Oral Health, 5. https://doi.org/10.3389/froh.2024.1453665

Vancouver

Zhu Z, Zhong L, Zhao Y, Wang X, Qian W, Ye N. Mapping optimal orthodontic implant sites in the palate using cone-beam computed tomography. Frontiers in Oral Health. 2024;5. doi:10.3389/froh.2024.1453665

BibTeX
@article{Zhu2024,
  author = {Zhu, Zhengxian and Zhong, Lin and Zhao, Yicheng and Wang, Xiaoting and Qian, Wenhao and Ye, Niansong},
  title = {Mapping optimal orthodontic implant sites in the palate using cone-beam computed tomography},
  journal = {Frontiers in Oral Health},
  year = {2024},
  volume = {5},
  doi = {10.3389/froh.2024.1453665}
}
Kostenlos starten →