Fachartikel in der Zeitschrift Annals of African Medicine, online erschienen am 01.07.2026. Verfasst von Abdullah Alshamrani und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, King Faisal University, Al-Ahsa, Saudi Arabia.
Abstract (Originalsprache)
Introduction
Finite element analysis (FEA) is a widely used method to evaluate the biomechanical aspects of dental implants; however, its clinical reliability depends on experimental validation. With the introduction of three-dimensional (3D) printing, customized implants offer potential improvements in stress distribution. The study was done to evaluate and compare stress distribution in conventional and 3D-printed implant models using FEA. Materials and Methods: An experimental research was done with a sample size of 480 observations. 3D implant models were developed and analyzed using ANSYS Workbench under simulated loading conditions (100–150 N). An in vitro validation was performed using strain gauges under mechanical loading. Statistical analysis was conducted using IBM SPSS version 25.0 with P < 0.05.
Results
The 3D-printed implant models demonstrated significantly lower stress values across all regions, particularly at the crestal bone. In vitro strain values were also reduced in the 3D group. A strong positive correlation was found between FEA and experimental findings ( r = 0.872, P = 0.001).
Conclusion
3D-printed implants exhibit improved biomechanical performance with reduced stress concentration and strong validation of FEA outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, King Faisal University, Al-Ahsa, Saudi Arabia.
- Department of Periodontology and Implant Dentistry, Qassim University, Buraydah, Saudi Arabia.
- Department of Prosthetic Dentistry, College of Dentistry, Qassim University, Buraydah, Saudi Arabia.
- Department of Periodontics, Ragas Dental College and Hospital, Chennai, Tamil Nadu, India.
- Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa, Saudi Arabia.
- Department of Biomedical Sciences, College of Medicine, King Faisal University, Al-Ahsa, Saudi Arabia.
Zitieren
APA
Alshamrani, A., Jasthi, V. C., Tabasum, S. T., Shujaulla, S., Syed, N. K., Seshadri, P. R., Nagaraja, S., & Meravanige, G. (2026). Assessment of Stress Distribution in Three-dimensional-printed Implant Models Using Finite Element Analysis. Annals of African Medicine. https://doi.org/10.4103/aam.aam_456_26
Vancouver
Alshamrani A, Jasthi VC, Tabasum ST, Shujaulla S, Syed NK, Seshadri PR, et al. Assessment of Stress Distribution in Three-dimensional-printed Implant Models Using Finite Element Analysis. Annals of African Medicine. 2026. doi:10.4103/aam.aam_456_26
BibTeX
@article{Alshamrani2026,
author = {Alshamrani, Abdullah and Jasthi, Veeriah Chowdary and Tabasum, Syeda Tawkhira and Shujaulla, Syed and Syed, Nubesh Khan and Seshadri, Pavithra Rangarajan and Nagaraja, Sreeharsha and Meravanige, Girish},
title = {Assessment of Stress Distribution in Three-dimensional-printed Implant Models Using Finite Element Analysis},
journal = {Annals of African Medicine},
year = {2026},
doi = {10.4103/aam.aam_456_26}
}
EUVIMED