EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY-NC 4.0

Feasibility of a Novel In-situ Local Tumor Ablation and Recycling Machine Based on Radiofrequency Dielectric Heating: In-depth Review on Research Background and Preliminary Report of an Experimental Study

Min Wook Joo iD, Sangrok Jin iD, Gyeong-Jun Lee iD, Yong-Suk Lee iD, Yang-Guk Chung iD

Clinics in Orthopedic Surgery · 2024

DOI: 10.4055/cios23186 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Clinics in Orthopedic Surgery, 2024. Verfasst von Min Wook Joo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, College of Medicine, The Catholic University of Korea, Seoul, Korea. Hauptthemen laut MEDLINE: Catheter Ablation, Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: St. Vincent’s Hospital, Research Institute of Medical Science Foundation, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In bone sarcomas, chemotherapy has improved the prognosis with advances in diagnostic and surgical technologies, which has led to attempts to save limbs. As early detection and multidisciplinary treatment have improved the survival rate, curative surgery is considered for selected patients with metastatic bone carcinomas. Limb salvage procedures may vary in relation to the reconstruction method, which is accompanied by different complications. To overcome them, we devised a novel concept, in-situ local tumor ablation and recycling machine based on radiofrequency (RF)-induced heating and intended experiments to demonstrate its feasibility.

Methods

The fresh femurs of 6-month-old pigs were used after removing the epiphyses; the distal parts were placed in a heating chamber. Fiber-optic temperature sensors were inserted in the metaphysis, meta-diaphysis, and diaphysis. Temperatures were measured six times each during heating at 27.12 MHz at various powers. Additionally, the compressive and bending stiffnesses were measured six times each for the unprocessed, RF-treated, and pasteurized bones, and the results were compared.

Results

Under 200 W power output, the temperatures at all measurement sites reached 70 ℃ or higher in 6 minutes, and the temperatures were maintained. The median compressive stiffness of RF-heated bones was 79.2% higher than that of pasteurized bones, but the difference was statistically insignificant. The median bending stiffness of RF-heated bones was approximately 66.3% of that of unprocessed bones, which was 20% higher than that of pasteurized bones.

Conclusions

The feasibility to rapidly attain and maintain temperatures for tumor ablation is shown, which favorably preserves bone stiffness through the in-situ local tumor ablation and recycling based on RF heating. The problem of nonuniform temperature distribution might be solved by an optimal design determined from simulation research and additional experiments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationNeoplasmsAnimalsComputer SimulationFeasibility StudiesHeatingHot TemperatureSwine

Stichwörter der Autor:innen

Ablation techniqueAutograftBone neoplasmsHeatingRadiofrequency ablation

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Department of Orthopaedic Surgery, St. Vincent's Hospital, Suwon, Korea.
  • School of Mechanical Engineering, Pusan National University, Busan, Korea.
  • Department of Orthopaedic Surgery, Incheon St. Mary's Hospital, Incheon, Korea.
  • Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, Seoul, Korea.

ORCID-Profile: Min Wook Joo, Sangrok Jin, Gyeong-Jun Lee, Yong-Suk Lee, Yang-Guk Chung

Förderung

  • St. Vincent’s Hospital, Research Institute of Medical Science Foundation
  • National Research Foundation of Korea

Zitieren

APA

Joo, M. W., Jin, S., Lee, G. J., Lee, Y. S., & Chung, Y. G. (2024). Feasibility of a Novel In-situ Local Tumor Ablation and Recycling Machine Based on Radiofrequency Dielectric Heating: In-depth Review on Research Background and Preliminary Report of an Experimental Study. Clinics in Orthopedic Surgery. https://doi.org/10.4055/cios23186

Vancouver

Joo MW, Jin S, Lee GJ, Lee YS, Chung YG. Feasibility of a Novel In-situ Local Tumor Ablation and Recycling Machine Based on Radiofrequency Dielectric Heating: In-depth Review on Research Background and Preliminary Report of an Experimental Study. Clinics in Orthopedic Surgery. 2024. doi:10.4055/cios23186

BibTeX
@article{Joo2024,
  author = {Joo, Min Wook and Jin, Sangrok and Lee, Gyeong-Jun and Lee, Yong-Suk and Chung, Yang-Guk},
  title = {Feasibility of a Novel In-situ Local Tumor Ablation and Recycling Machine Based on Radiofrequency Dielectric Heating: In-depth Review on Research Background and Preliminary Report of an Experimental Study},
  journal = {Clinics in Orthopedic Surgery},
  year = {2024},
  doi = {10.4055/cios23186}
}
Kostenlos starten →