Marginal and internal fit of 3D printed provisional crowns according to build directions
The Journal of Advanced Prosthodontics · 2020 · 12 (4) · 225
DOI: 10.4047/jap.2020.12.4.225 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Advanced Prosthodontics, 2020. Verfasst von Ji-Eun Ryu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dentistry, Wonkwang University, Iksan, Republic of Korea. Die Arbeit wurde bisher 75-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
PURPOSE: This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS: The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS: MG, CG, and OG were significantly different by build angle groups (P
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, School of Dentistry, Wonkwang University, Iksan, Republic of Korea.
- Department of Conservative Dentistry, School of Dentistry, Chonnam National University, Gwangju, Rupublic of Korea.
ORCID-Profile: Ji-Eun Ryu, Yu-Lee Kim, Hyun-Jun Kong, Hoon-Sang Chang, Ji-Hye Jung
Förderung
- National Research Foundation of Korea
Zitieren
APA
Ryu, J. E., Kim, Y. L., Kong, H. J., Chang, H. S., & Jung, J. H. (2020). Marginal and internal fit of 3D printed provisional crowns according to build directions. The Journal of Advanced Prosthodontics, 12(4), 225. https://doi.org/10.4047/jap.2020.12.4.225
Vancouver
Ryu JE, Kim YL, Kong HJ, Chang HS, Jung JH. Marginal and internal fit of 3D printed provisional crowns according to build directions. The Journal of Advanced Prosthodontics. 2020;12(4):225. doi:10.4047/jap.2020.12.4.225
BibTeX
@article{Ryu2020,
author = {Ryu, Ji-Eun and Kim, Yu-Lee and Kong, Hyun-Jun and Chang, Hoon-Sang and Jung, Ji-Hye},
title = {Marginal and internal fit of 3D printed provisional crowns according to build directions},
journal = {The Journal of Advanced Prosthodontics},
year = {2020},
volume = {12},
number = {4},
pages = {225},
doi = {10.4047/jap.2020.12.4.225}
}
EUVIMED