Manifold-based denoising for Ferumoxytol-enhanced 3D cardiac cine MRI

Anna Andrews, Pezad Doctor, Lasya Gaur, F Gerald Greil, Tarique Hussain, Qing Zou

Mathematical Biosciences and Engineering · 2024

DOI: 10.3934/mbe.2024163 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mathematical Biosciences and Engineering, 2024. Verfasst von Anna Andrews und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Mercer University, Macon, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cine, Ferrosoferric Oxide. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The two-dimensional (2D) cine cardiovascular magnetic resonance (CMR) technique is the reference standard for assessing cardiac function. However, one challenge with 2D cine is that the acquisition time for the whole cine stack is long and requires multiple breath holds, which may not be feasible for pediatric or ill patients. Though single breath-hold multi-slice cine may address the issue, it can only acquire low-resolution images, and hence, affect the accuracy of cardiac function assessment. To address these challenges, a Ferumoxytol-enhanced, free breathing, isotropic high-resolution 3D cine technique was developed. The method produces high-contrast cine images with short acquisition times by using compressed sensing together with a manifold-based method for image denoising. This study included fifteen patients (9.1 $ \pm $ 5.6 yrs.) who were referred for clinical cardiovascular magnetic resonance imaging (MRI) with Ferumoxytol contrast and were prescribed the 3D cine sequence. The data was acquired on a 1.5T scanner. Statistical analysis shows that the manifold-based denoised 3D cine can accurately measure ventricular function with no significant differences when compared to the conventional 2D breath-hold (BH) cine. The multiplanar reconstructed images of the proposed 3D cine method are visually comparable to the golden standard 2D BH cine method in terms of clarity, contrast, and anatomical precision. The proposed method eliminated the need for breath holds, reduced scan times, enabled multiplanar reconstruction within an isotropic data set, and has the potential to be used as an effective tool to access cardiovascular conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance Imaging, CineFerrosoferric OxideHumansChildImaging, Three-DimensionalHeartRespirationReproducibility of Results

Stichwörter der Autor:innen

3D cineFerumoxytolconvolutional neural networkmanifold assumption

Substanzen

Ferrosoferric Oxide

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Mercer University, Macon, USA.
  • Division of Pediatric Cardiology, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, TX, USA.
  • Department of Radiology, The University of Texas Southwestern Medical Center, Dallas, TX, USA.
  • Advanced Imaging Research Center, The University of Texas Southwestern Medical Center, Dallas, TX, USA.

Zitieren

APA

Andrews, A., Doctor, P., Gaur, L., Greil, F. G., Hussain, T., & Zou, Q. (2024). Manifold-based denoising for Ferumoxytol-enhanced 3D cardiac cine MRI. Mathematical Biosciences and Engineering. https://doi.org/10.3934/mbe.2024163

Vancouver

Andrews A, Doctor P, Gaur L, Greil FG, Hussain T, Zou Q. Manifold-based denoising for Ferumoxytol-enhanced 3D cardiac cine MRI. Mathematical Biosciences and Engineering. 2024. doi:10.3934/mbe.2024163

BibTeX
@article{Andrews2024,
  author = {Andrews, Anna and Doctor, Pezad and Gaur, Lasya and Greil, F Gerald and Hussain, Tarique and Zou, Qing},
  title = {Manifold-based denoising for Ferumoxytol-enhanced 3D cardiac cine MRI},
  journal = {Mathematical Biosciences and Engineering},
  year = {2024},
  doi = {10.3934/mbe.2024163}
}
Kostenlos starten →