CFD Analysis of Indoor Ventilation for Airborne Virus Infection
Journal of Advanced Research in Numerical Heat Transfer · 2023
DOI: 10.37934/arnht.14.1.116 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Advanced Research in Numerical Heat Transfer, 2023. Verfasst von Kaishan Feng und 7 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref).
Abstract (Originalsprache)
CFD Analysis of Indoor Ventilation for Airborne Virus Infection Indoor airflow patterns and air residence times significantly influence the spread of airborne infectious viruses, such as COVID-19. These factors can be quantified using computational fluid dynamics (CFD). In this study, CFD was utilized to assess the indoor airflow patterns and calculate air residence times in a typical restroom with high personnel flow and low ventilation efficiency. The results identified regions with high air residence times, indicating potential risk areas for airborne virus retention. Furthermore, the effects of different ventilation strategies on these high-risk areas were analyzed. Despite meeting air change standards, certain regions were found to potentially pose a higher risk due to prolonged air residence times. Based on these findings, recommendations for improving ventilation systems to reduce the risk of airborne virus infection were proposed. This study highlights the necessity of a more nuanced approach to indoor air assessment than simply calculating air changes per hour. It was concluded that (1) different ventilation strategies can greatly affect the air residence time in the room and (2) the variance of air residence time in the air circulation area are large in some locations, even with simple ventilation adjustments.
Zitieren
APA
Feng, K., Yanagita, Y., Miyamura, Y., Basri, A. A., Zuber, M., Rohani, S., Ahmad, K. A., & Tamagawa, M. (2023). CFD Analysis of Indoor Ventilation for Airborne Virus Infection. Journal of Advanced Research in Numerical Heat Transfer. https://doi.org/10.37934/arnht.14.1.116
Vancouver
Feng K, Yanagita Y, Miyamura Y, Basri AA, Zuber M, Rohani S, et al. CFD Analysis of Indoor Ventilation for Airborne Virus Infection. Journal of Advanced Research in Numerical Heat Transfer. 2023. doi:10.37934/arnht.14.1.116
BibTeX
@article{Feng2023,
author = {Feng, Kaishan and Yanagita, Yoshiki and Miyamura, Yuko and Basri, Adi Azriff and Zuber, Mohammad and Rohani, Siti and Ahmad, Kamarul Arifin and Tamagawa, Masaaki},
title = {CFD Analysis of Indoor Ventilation for Airborne Virus Infection},
journal = {Journal of Advanced Research in Numerical Heat Transfer},
year = {2023},
doi = {10.37934/arnht.14.1.116}
}
EUVIMED