EUVIMEDEUVIMED entdecken
Open Access

A CFD-based framework to assess airborne infection risk in buildings

Giulio Vita, Darren Woolf, Thomas Avery-Hickmott, Rob Rowsell

Building and Environment · 2023-04 · 233 · 110099

DOI: 10.1016/j.buildenv.2023.110099 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Building and Environment, 2023-04. Verfasst von Giulio Vita und 3 weiteren Autor:innen. Beteiligte Einrichtung: Wirth Research Ltd, Charlotte Avenue, Bicester, OX27 8BL, United Kingdom. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: EPSRC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The COVID-19 pandemic has prompted huge efforts to further the scientific knowledge of indoor ventilation and its relationship to airborne infection risk. Exhaled infectious aerosols are spread and inhaled as a result of room airflow characteristics. Many calculation methods and assertions on risk assume 'well-mixed' flow conditions. However, ventilation in buildings is complex and often not showing well-mixed conditions. Ventilation guidance is typically based on the provision of generic minimum ventilation flow rates for a given space, irrespective of the effectiveness in the delivery of the supply air. Furthermore, the airflow might be heavily affected by the season, the HVAC ventilation, or the opening of windows, which would potentially generate draughts and non-uniform conditions. As a result, fresh air concentration would be variable depending upon a susceptible receptor's position in a room and, therefore, associated airborne infection risk. A computational fluid dynamics (CFD) and dynamic thermal modelling (DTM) framework is proposed to assess the influence of internal airflow characteristics on airborne infection risk. A simple metric is proposed, the hourly airborne infection rate (HAI) which can easily help designers to stress-test the ventilation within a building under several conditions. A case study is presented, and the results clearly demonstrate the importance of understanding detailed indoor airflow characteristics and associated concentration patterns in order to provide detailed design guidance, e.g. occupancy, supply air diffusers and furniture layouts, to reduce airborne infection risk.

Schlagwörter

Stichwörter der Autor:innen

Airborne infection riskCFDCOVID-19Dynamic thermal modellingIndoor ventilationResilience

Autor:innen und Institutionen

  • Wirth Research Ltd, Charlotte Avenue, Bicester, OX27 8BL, United Kingdom.
  • University of Birmingham School of Engineering Edgbaston, Birmingham, B15 2TT, United Kingdom.

Förderung

  • EPSRC

Zitieren

APA

Vita, G., Woolf, D., Avery-Hickmott, T., & Rowsell, R. (2023). A CFD-based framework to assess airborne infection risk in buildings. Building and Environment, 233, 110099. https://doi.org/10.1016/j.buildenv.2023.110099

Vancouver

Vita G, Woolf D, Avery-Hickmott T, Rowsell R. A CFD-based framework to assess airborne infection risk in buildings. Building and Environment. 2023;233:110099. doi:10.1016/j.buildenv.2023.110099

BibTeX
@article{Vita2023,
  author = {Vita, Giulio and Woolf, Darren and Avery-Hickmott, Thomas and Rowsell, Rob},
  title = {A CFD-based framework to assess airborne infection risk in buildings},
  journal = {Building and Environment},
  year = {2023},
  volume = {233},
  pages = {110099},
  doi = {10.1016/j.buildenv.2023.110099}
}
Kostenlos starten →