EUVIMEDScopri EUVIMED
Video/Audio

Imaging of the Microstructural Failure Mechanism in the Human Hip

Saulo Martelli, Egon Perilli

Journal of Visualized Experiments · 2023

DOI: 10.3791/64947 ↗

At a glance

Video/Audio in Journal of Visualized Experiments, 2023. Written by Saulo Martelli and 1 co-authors. Institution: School of Mechanical, Medical and Process Engineering, Queensland University of Technology; Medical Device Research Institute, College of Science and…. Major MEDLINE topics: Fractures, Bone. Cited 1 times so far (Crossref); 15 references.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Imaging the bone microstructure under progressively increasing loads allows for observing the microstructural failure behavior of bone. Here, we describe a protocol for obtaining a sequence of three-dimensional microstructural images of the entire proximal femur under progressively increasing deformation, causing clinically relevant fractures of the femoral neck. The protocol is demonstrated using four femora from female donors aged 66-80 years at the lower end of bone mineral density in the population (T-score range = -2.09 to -4.75). A radio-transparent compressive stage was designed for loading the specimens replicating a one-leg stance, while recording the applied load during micro-computed tomography (micro-CT) imaging. The field of view was 146 mm wide and 132 mm high, and the isotropic pixel size was 0.03 mm. The force increment was based on finite-element predictions of the fracture load. The compressive stage was used to apply the displacement to the specimen and enact the prescribed force increments. Sub-capital fractures due to opening and shear of the femoral neck occurred after four to five load increments. The micro-CT images and the reaction force measurements were processed to study the bone strain and energy absorption capacity. Instability of the cortex appeared at the early loading steps. The subchondral bone in the femoral head displayed large deformations reaching 16% before fracture, and a progressive increase in the support capacity up to fracture. The deformation energy linearly increased with the displacement up to fracture, while the stiffness decreased to near-zero values immediately before fracture. Three-fourths of the fracture energy was taken by the specimen during the final 25% force increment. In conclusion, the protocol developed revealed a remarkable energy absorption capacity, or damage tolerance, and a synergic interaction between the cortical and trabecular bone at an advanced donor age.

Subjects

MeSH terms (MEDLINE)

Fractures, BoneHumansFemaleX-Ray MicrotomographyFemurFemur NeckBone DensityFinite Element Analysis

Authors and institutions

  • School of Mechanical, Medical and Process Engineering, Queensland University of Technology; Medical Device Research Institute, College of Science and Engineering, Flinders University; saulo.martelli@qut.edu.au.
  • Medical Device Research Institute, College of Science and Engineering, Flinders University; egon.perilli@flinders.edu.au.

Cite

APA

Martelli, S., & Perilli, E. (2023). Imaging of the Microstructural Failure Mechanism in the Human Hip. Journal of Visualized Experiments. https://doi.org/10.3791/64947

Vancouver

Martelli S, Perilli E. Imaging of the Microstructural Failure Mechanism in the Human Hip. Journal of Visualized Experiments. 2023. doi:10.3791/64947

BibTeX
@article{Martelli2023,
  author = {Martelli, Saulo and Perilli, Egon},
  title = {Imaging of the Microstructural Failure Mechanism in the Human Hip},
  journal = {Journal of Visualized Experiments},
  year = {2023},
  doi = {10.3791/64947}
}
Start for free →