EUVIMEDEUVIMED entdecken
Crossref

Effect of Postoperative Neck‐Shaft and Anteversion Angles on Biomechanical Outcomes in Proximal Femoral Osteotomy: An In Silico Study

Alireza Y Bavil iD, Emmanuel Eghan-Acquah, Laura E Diamond iD, Rod Barrett, David Bade, Christopher P Carty, Stefanie Feih, David J Saxby iD

Journal of Orthopaedic Research · 2025

DOI: 10.1002/jor.26043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2025. Verfasst von Alireza Y Bavil und 7 weiteren Autor:innen. Beteiligte Einrichtung: Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia. Hauptthemen laut MEDLINE: Osteotomy, Femur, Femur Neck. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: This study was funded by the Australian Research Council Industrial Transformation Training Centres, Centre for Medical Implant Technologies (CMIT) (IC18010002….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Effective surgical planning is crucial for maximizing patient outcomes following complex orthopedic procedures such as proximal femoral osteotomy. In silico simulations can be used to assess how surgical variations in proximal femur geometry, such as femur neck‐shaft and anteversion angles, affect postoperative system mechanics. This study investigated the sensitivity of femur mechanics to postoperative neck‐shaft angles, anteversion angles, and osteotomy contact areas using patient‐specific finite element analysis informed by neuromusculoskeletal models. A sequential neuromusculoskeletal modeling and finite element analysis pipeline was used to simulate postoperative mechanics in three pediatric patients with varying demographic and anatomic features. Nine surgical configurations derived from permutations of the clinical envelope of neck‐shaft angles and anteversion angles were simulated for the stance phase of gait. The outcome mechanics assessed were peak von Mises stresses on the bone‐implant contact surfaces as well as interfragmentary movement and strain on the osteotomy location. Peak von Mises stress and interfragmentary movement and strain were on average 38% more sensitive to surgical variation in neck‐shaft angle compared to anteversion angle. A significant negative correlation was detected between contact area and interfragmentary movement ( r = −0.90, p < 0.0001) and strain ( r = −0.45, p = 0.017). Overall findings suggest neck‐shaft angle significantly influences postoperative femur mechanics and highlight the importance of maximizing contact area to limit interfragmentary motion and foster an optimal mechanical environment for bone healing and callus formation following proximal femoral osteotomy. Between‐patient variation in sensitivity to proximal femoral geometry reinforced the importance of patient‐specific surgical planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OsteotomyFemurFemur NeckHumansBiomechanical PhenomenaFinite Element AnalysisMaleChildComputer SimulationFemale

Stichwörter der Autor:innen

bone healingdigital twingaitneuromusculoskeletal mechanicspediatric orthopedics

Autor:innen und Institutionen

  • Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia.
  • School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia.
  • Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia.
  • Department of Orthopaedics, Children's Health Queensland Hospital and Health Service, South Brisbane, Australia.
  • School of Medicine and Dentistry, Griffith University, Gold Coast, Australia.
  • School of Engineering and Build Environment, Griffith University, Gold Coast, Australia.

ORCID-Profile: Alireza Y Bavil, Laura E Diamond, David J Saxby

Förderung

  • This study was funded by the Australian Research Council Industrial Transformation Training Centres, Centre for Medical Implant Technologies (CMIT) (IC18010002…

Zitieren

APA

Bavil, A. Y., Eghan-Acquah, E., Diamond, L. E., Barrett, R., Bade, D., Carty, C. P., Feih, S., & Saxby, D. J. (2025). Effect of Postoperative Neck‐Shaft and Anteversion Angles on Biomechanical Outcomes in Proximal Femoral Osteotomy: An In Silico Study. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.26043

Vancouver

Bavil AY, Eghan-Acquah E, Diamond LE, Barrett R, Bade D, Carty CP, et al. Effect of Postoperative Neck‐Shaft and Anteversion Angles on Biomechanical Outcomes in Proximal Femoral Osteotomy: An In Silico Study. Journal of Orthopaedic Research. 2025. doi:10.1002/jor.26043

BibTeX
@article{Bavil2025,
  author = {Bavil, Alireza Y and Eghan-Acquah, Emmanuel and Diamond, Laura E and Barrett, Rod and Bade, David and Carty, Christopher P and Feih, Stefanie and Saxby, David J},
  title = {Effect of Postoperative Neck‐Shaft and Anteversion Angles on Biomechanical Outcomes in Proximal Femoral Osteotomy: An In Silico Study},
  journal = {Journal of Orthopaedic Research},
  year = {2025},
  doi = {10.1002/jor.26043}
}
Kostenlos starten →