Experimental evaluation of corrosion resistance of the alloys used in the fixed dental prosthesis
Romanian Journal of Stomatology · 2015
DOI: 10.37897/rjs.2015.2.1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Romanian Journal of Stomatology, 2015. Verfasst von Costin Coman und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
Objectives
In this study we evaluated corrosion resistance of three types of metal alloys (two NiCr and one CoCr).
Methods
Samples (coded A, B, C) of circular shape, with dimensions 13 x 1.5 mm, sanded and polished, were introduced in Fusayama Meyer artificial saliva at pH 5.2 and 37 ± 0.5°C and tested in terms of corrosion resistance with a potentiostat/galvanostat (model 4000 PARSTAT, Princeton Applied Research).
Results
Open circuit potential EOC [mV] ranged between 21.316 and 5.75. Corrosion potential Ecor [mV] was between -73.536 and -395.662, and the corrosion current density icor [A/cm2] was between 1.237 x 10-6 and 905.13 x 10-9.
Conclusion
The best corrosion behavior in Fusayama Meyer artificial saliva at pH 5.2 and at a temperature of 37 ± 0.5°C is the alloy A, followed by the alloy C.
Zitieren
APA
Coman, C., Comăneanu, R. M., Hâncu, V., Barbu, H. M., Cotruţ, C., & Ghergic, D. L. (2015). Experimental evaluation of corrosion resistance of the alloys used in the fixed dental prosthesis. Romanian Journal of Stomatology. https://doi.org/10.37897/rjs.2015.2.1
Vancouver
Coman C, Comăneanu RM, Hâncu V, Barbu HM, Cotruţ C, Ghergic DL. Experimental evaluation of corrosion resistance of the alloys used in the fixed dental prosthesis. Romanian Journal of Stomatology. 2015. doi:10.37897/rjs.2015.2.1
BibTeX
@article{Coman2015,
author = {Coman, Costin and Comăneanu, Raluca Monica and Hâncu, Violeta and Barbu, Horia Mihail and Cotruţ, Cosmin and Ghergic, Doina Lucia},
title = {Experimental evaluation of corrosion resistance of the alloys used in the fixed dental prosthesis},