Evaluation of the Corrosion Resistance of Different Types of Orthodontic Fixed Retention Appliances: A Preliminary Laboratory Study
Journal of Functional Biomaterials · 31.01.2023 · 14 (2) · 81
DOI: 10.3390/jfb14020081 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 31.01.2023. Verfasst von Busra Kumrular und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Faculty of Dentistry, Zonguldak Bulent Ecevit University, Zonguldak 67100, Turkey. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
(i)
Objective
The present study aimed to compare the electrochemical corrosion resistance of six different types of fixed lingual retainer wires used as fixed retention appliances in an in vitro study. (ii)
Methods
In the study, two different Ringer solutions, with pH 7 and pH 3.5, were used. Six groups were formed with five retainer wires in each group. In addition, 3-braided stainless steel, 6-braided stainless steel, Titanium Grade 1, Titanium Grade 5, Gold, and Dead Soft retainer wires were used. The corrosion current density (icorr), corrosion rate (CR), and polarization resistance (Rp) were determined from the Tafel polarization curves. (iii)
Results
The corrosion current density of the Gold retainer group was statistically higher than the other retainer groups in both solutions (p < 0.05). The corrosion rate of the Dead Soft retainer group was statistically higher than the other retainer groups in both solutions (p < 0.05). The polarization resistance of the Titanium Grade 5 retainer group was statistically higher than the other retainer groups in both solutions (p < 0.05). As a result of Scanning Electron Microscope (SEM) images, pitting corrosion was not observed in the Titanium Grade 1, Titanium Grade 5 and Gold retainer groups, while pitting corrosion was observed in the other groups. (iv)
Conclusion
From a corrosion perspective, although the study needs to be evaluated in vivo, the Titanium Grade 5 retainer group included is in this in vitro study may be more suitable for clinical use due to its high electrochemical corrosion resistance and the lack of pitting corrosion observed in the SEM images.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, Faculty of Dentistry, Zonguldak Bulent Ecevit University, Zonguldak 67100, Turkey.
- Department of Metallurgical and Materials Engineering, Faculty of Engineering, Zonguldak Bulent Ecevit University, Zonguldak 67100, Turkey.
- Department of Orthodontics, Faculty of Dentistry, Tekirdag Namık Kemal University, Tekirdağ 59030, Turkey.
ORCID-Profile: Orhan Cicek, İlker Emin Dağ, Baris Avar
Zitieren
APA
Kumrular, B., Cicek, O., Dağ, İ. E., Avar, B., & Erener, H. (2023). Evaluation of the Corrosion Resistance of Different Types of Orthodontic Fixed Retention Appliances: A Preliminary Laboratory Study. Journal of Functional Biomaterials, 14(2), 81. https://doi.org/10.3390/jfb14020081
Vancouver
Kumrular B, Cicek O, Dağ İE, Avar B, Erener H. Evaluation of the Corrosion Resistance of Different Types of Orthodontic Fixed Retention Appliances: A Preliminary Laboratory Study. Journal of Functional Biomaterials. 2023;14(2):81. doi:10.3390/jfb14020081
BibTeX
@article{Kumrular2023,
author = {Kumrular, Busra and Cicek, Orhan and Dağ, İlker Emin and Avar, Baris and Erener, Hande},
title = {Evaluation of the Corrosion Resistance of Different Types of Orthodontic Fixed Retention Appliances: A Preliminary Laboratory Study},
journal = {Journal of Functional Biomaterials},
year = {2023},
volume = {14},
number = {2},
pages = {81},
doi = {10.3390/jfb14020081}
}