EUVIMEDEUVIMED entdecken
Crossref

Wear Resistance Under High Load Forces of Four Different Polyethylene Terephthalate Glycol Vacuum-Formed Orthodontic Retainers

Dana Cristina Bratu, Vlad Florin Vinatu, Silvia Izabella Pop, Pompiliu Horatiu Petrescu, Catalin Petru Simon, George Popa

Materiale Plastice · 30.09.2019 · 56 (3) · 505-509

DOI: 10.37358/mp.19.3.5218 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materiale Plastice, online erschienen am 30.09.2019. Verfasst von Dana Cristina Bratu und 5 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of our study was to determine the wear resistance of vacuum-formed retainers (VFRs) made out of polyethylene terephthalate glycol (PETG), from four different manufacturers (Essix, Leone, Erkodent, Bio-Art), under high load forces (600 N), for 10000 cycles. Forty thermoplastic sheets were divided in four groups, each group consisting of a set of ten sheets from each manufacturer, thermoformed on two matching study models with an ideal occlusion. The Instron 8874 equipment was used to simulate the accelerated wear of VFR surfaces. The surfaces of the VFRs were visually inspected using a KEYENCE VHX-600 digital microscope, but this proved difficult because of the surface shine. 3D models were generated using a GOM industrial laser surface scanner. Several wear areas were identified, having various degrees of roughness, with no evident tear points or perforations. One-way ANOVA analysis showed no statistically significant differences in net mass loss between the four groups.

Zitieren

APA

Bratu, D. C., Vinatu, V. F., Pop, S. I., Petrescu, P. H., Simon, C. P., & Popa, G. (2019). Wear Resistance Under High Load Forces of Four Different Polyethylene Terephthalate Glycol Vacuum-Formed Orthodontic Retainers. Materiale Plastice, 56(3), 505-509. https://doi.org/10.37358/mp.19.3.5218

Vancouver

Bratu DC, Vinatu VF, Pop SI, Petrescu PH, Simon CP, Popa G. Wear Resistance Under High Load Forces of Four Different Polyethylene Terephthalate Glycol Vacuum-Formed Orthodontic Retainers. Materiale Plastice. 2019;56(3):505-509. doi:10.37358/mp.19.3.5218

BibTeX
@article{Bratu2019,
  author = {Bratu, Dana Cristina and Vinatu, Vlad Florin and Pop, Silvia Izabella and Petrescu, Pompiliu Horatiu and Simon, Catalin Petru and Popa, George},
  title = {Wear Resistance Under High Load Forces of Four Different Polyethylene Terephthalate Glycol Vacuum-Formed Orthodontic Retainers},
  journal = {Materiale Plastice},
  year = {2019},
  volume = {56},
  number = {3},
  pages = {505--509},
  doi = {10.37358/mp.19.3.5218}
}
Kostenlos starten →