EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Different Perception on the Use of Hawley and Vacuum-formed Retainers Amongst Post-orthodontic Patients. Part 1: Discomfort and Aesthetic Perception

Andina Alia Latief, Benny Mulyono Soegiharto, Fadli Jazaldi

Journal of Indian Orthodontic Society · 2024-04 · 58 (2) · 126-133

DOI: 10.1177/03015742231214391 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Indian Orthodontic Society, online erschienen am 15.01.2024. Verfasst von Andina Alia Latief und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Backgrounds and Objectives The use of a retainer in the retention phase creates different perceptions amongst patients. However, the evidence regarding it is limited. This research was conducted to analyze the difference in patients’ perception of discomfort and aesthetics between Hawley and vacuum-formed retainers.

Methods

This study included 80 patients ( n per group = 40). Patients were invited to participate if they had completed their treatment for 6 months to 5 years and complied with the inclusion criteria. Seven questions were given to the patients using a digital-based questionnaire. Each was asked twice to address both maxillary and mandibular retainers. Responses were measured using the Visual Analogue Scale. Blinding was applied through data analysis.

Results

Statistically significant differences were found in the perception of the aesthetic, shape, and retainer color. Statistically significant differences were not found in the perception of comfort, pain, sharpness, pressure, presence of soft tissue cut, and confidence level with the retainer in place. No harm was observed to any patients during the study.

Conclusions

Vacuum-formed retainers (VFRs) were more acceptable than Hawley retainers (HRs) regarding the retainer’s aesthetic, shape, and color. There were no significant differences between HRs and VFRs regarding patient perception of discomfort and confidence when using the retainer.

Zitieren

APA

Latief, A. A., Soegiharto, B. M., & Jazaldi, F. (2024). Different Perception on the Use of Hawley and Vacuum-formed Retainers Amongst Post-orthodontic Patients. Part 1: Discomfort and Aesthetic Perception. Journal of Indian Orthodontic Society, 58(2), 126-133. https://doi.org/10.1177/03015742231214391

Vancouver

Latief AA, Soegiharto BM, Jazaldi F. Different Perception on the Use of Hawley and Vacuum-formed Retainers Amongst Post-orthodontic Patients. Part 1: Discomfort and Aesthetic Perception. Journal of Indian Orthodontic Society. 2024;58(2):126-133. doi:10.1177/03015742231214391

BibTeX
@article{Latief2024,
  author = {Latief, Andina Alia and Soegiharto, Benny Mulyono and Jazaldi, Fadli},
  title = {Different Perception on the Use of Hawley and Vacuum-formed Retainers Amongst Post-orthodontic Patients. Part 1: Discomfort and Aesthetic Perception},
  journal = {Journal of Indian Orthodontic Society},
  year = {2024},
  volume = {58},
  number = {2},
  pages = {126--133},
  doi = {10.1177/03015742231214391}
}
Kostenlos starten →