Algorithmic Determination of Femoral Neck Axis in Birmingham Hip Resurfacing: A Parametric CAD-Based Method
Acta of Bioengineering and Biomechanics · 18.05.2026 · 28 (2)
DOI: 10.37190/abb/221630 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta of Bioengineering and Biomechanics, online erschienen am 18.05.2026. Verfasst von Michał P Kowalik und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Aeronautics and Applied Mechanics (IAAM), Warsaw University of Technology, Warsaw, Poland. Hauptthemen laut MEDLINE: Algorithms, Femur Neck, Arthroplasty, Replacement, Hip, Computer-Aided Design.
Abstract (Originalsprache)
Purpose
Birmingham Hip Resurfacing requires precise determination of the femoral head-neck axis to minimize risks of neck fracture, cortical notching, and component malposition. Existing methods rely on intraoperative estimation, generic guides, or semi-manual planning, all susceptible to anatomical variability. This study presents an automated parametric algorithm for determining the femoral neck axis from CT-derived models to support patient-specific surgical planning.
Methods
The method utilizes segmented CT data converted to STEP format. Following artifact removal, the algorithm performs iterative cross-sectional analysis along the neck axis, identifying characteristic anatomical points: the neck isthmus, head centroid, and head apex. The axis is approximated from these points and refined through rotational optimization in 5 degree and 0.5 degree increments. The algorithm was evaluated on four femoral models in five spatial orientations each (20 test cases).
Results
The algorithm achieved a mean validation score of 4.1/5.0 (82%). Three models with high-quality meshes scored 4-5, while one model with extensive artifacts scored 1-2, confirming sensitivity to input data quality. Repeatability was plus/minus 0.5 degrees in angular orientation and plus/minus 0.2 mm in isthmus position. Error propagation analysis indicated that CT-induced uncertainty (approximately 1.6 degrees upper bound) constitutes the limiting factor, not algorithmic precision. Physical prototyping confirmed viability for patient-specific instrument design.
Conclusions
The method provides reproducible, automated femoral neck axis determination with plus/minus 0.5 degrees repeatability -- approximately three times smaller than CT-induced uncertainty and an order of magnitude below the 5-7 degree errors of conventional jigs. Future work should validate the method against clinical outcomes in larger cohorts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Aeronautics and Applied Mechanics (IAAM), Warsaw University of Technology, Warsaw, Poland.
- Łukasiewicz Research Network - Industrial Research Institute for Automation and Measurements PIAP, Warsaw, Poland.
Zitieren
APA
Kowalik, M. P., Knaś, D., & Zawiśliński, K. (2026). Algorithmic Determination of Femoral Neck Axis in Birmingham Hip Resurfacing: A Parametric CAD-Based Method. Acta of Bioengineering and Biomechanics, 28(2). https://doi.org/10.37190/abb/221630
Vancouver
Kowalik MP, Knaś D, Zawiśliński K. Algorithmic Determination of Femoral Neck Axis in Birmingham Hip Resurfacing: A Parametric CAD-Based Method. Acta of Bioengineering and Biomechanics. 2026;28(2). doi:10.37190/abb/221630
BibTeX
@article{Kowalik2026,
author = {Kowalik, Michał P and Knaś, Dawid and Zawiśliński, Krzysztof},
title = {Algorithmic Determination of Femoral Neck Axis in Birmingham Hip Resurfacing: A Parametric CAD-Based Method},
journal = {Acta of Bioengineering and Biomechanics},
year = {2026},
volume = {28},
number = {2},
doi = {10.37190/abb/221630}
}
EUVIMED