EUVIMEDEUVIMED entdecken
Crossref

The effect of acetabular shell and liner design on posterior horizontal dislocation distance in modern dual-mobility implants

Nathaniel T Ondeck iD, Drake G LeBrun, Shammodip Roy, Ahmad Faizan, Geoffrey H Westrich

HIP International · 2025

DOI: 10.1177/11207000251329269 ↗

Kurz gefasst

Fachartikel in der Zeitschrift HIP International, 2025. Verfasst von Nathaniel T Ondeck und 4 weiteren Autor:innen. Beteiligte Einrichtung: Adult Reconstruction Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA. Hauptthemen laut MEDLINE: Prosthesis Design, Hip Prosthesis, Acetabulum, Arthroplasty, Replacement, Hip. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The posterior horizontal dislocation distance (PHDD) is a 3-dimensional jump distance measurement that is relevant to the risk of dislocation. There are a number of dual-mobility (DM) constructs with varying designs available. The present study identifies design factors associated with increased PHDD and evaluates the PHDD of 3 DM implants.

Methods

3 different computer-aided implant designs were virtually implanted within a 3-dimensional CT-derived pelvic model. Each design represented an analogue of a DM system (MDM, OR3O, and G7) according to specific variations in acetabular liner rim build-up and femoral head centre location. The effective head diameters and PHDD values were calculated for each size acetabular shell and DM design.

Results

The positive rim build-up design (MDM) showed higher PHDD values as compared to the other 2 hemispherical rim designs with no build-up, across all studied shell sizes. Specifically, the MDM design analogue had 16.4–29.0% greater PHDD values than the OR3O design analog and 15.2–30.5% greater PHDD values than the G7 design analogue The effect of a sfemoral head centre location relative to the liner head centre (OR3O) was negated by a larger effective head diameter to shell diameter ratio of the G7 design, resulting in similar PHDD values.

Conclusions

Design parameters affect the PHDD values of DM cups. The use of an elevated rim was associated with greater PHDD values. A medialised femoral head centre should also improve PHDD values, but the effect was nullified due to consecutive lower effective head diameters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis DesignHip ProsthesisAcetabulumArthroplasty, Replacement, HipHip DislocationHumansTomography, X-Ray ComputedComputer-Aided DesignImaging, Three-Dimensional

Stichwörter der Autor:innen

Dislocationdual-mobility constructsinstabilitytotal hip arthroplasty

Autor:innen und Institutionen

  • Adult Reconstruction Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA.
  • Advanced Technology and Research Division, Stryker Orthopedics, Mahwah, NJ, USA.

ORCID-Profile: Nathaniel T Ondeck

Zitieren

APA

Ondeck, N. T., LeBrun, D. G., Roy, S., Faizan, A., & Westrich, G. H. (2025). The effect of acetabular shell and liner design on posterior horizontal dislocation distance in modern dual-mobility implants. HIP International. https://doi.org/10.1177/11207000251329269

Vancouver

Ondeck NT, LeBrun DG, Roy S, Faizan A, Westrich GH. The effect of acetabular shell and liner design on posterior horizontal dislocation distance in modern dual-mobility implants. HIP International. 2025. doi:10.1177/11207000251329269

BibTeX
@article{Ondeck2025,
  author = {Ondeck, Nathaniel T and LeBrun, Drake G and Roy, Shammodip and Faizan, Ahmad and Westrich, Geoffrey H},
  title = {The effect of acetabular shell and liner design on posterior horizontal dislocation distance in modern dual-mobility implants},
  journal = {HIP International},
  year = {2025},
  doi = {10.1177/11207000251329269}
}
Kostenlos starten →