Proximal femur parameter measurement via improved PointNet++
The International Journal of Medical Robotics and Computer Assisted Surgery · 2023
DOI: 10.1002/rcs.2494 ↗Kurz gefasst
Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2023. Verfasst von Jiayu Yang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer, Xi'an University of Posts and Telecommunications, Xi'an, Shaanxi, China. Hauptthemen laut MEDLINE: Femur, Arthroplasty, Replacement, Hip. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: Shaanxi Key Laboratory of Network Data Intelligent Processing.
Abstract (Originalsprache)
Background
Femoral morphological studies and parameter measurements play a crucial role in diagnosing hip joint disease, preoperative planning for total hip arthroplasty, and prosthesis design. Doctors usually perform parameter measurements manually in clinical practice, but it is time‐consuming and labor‐intensive. Moreover, the results rely heavily on the doctor's experience, and the repeatability is poor. Therefore, the accurate and automatic measurement methods of proximal femoral parameters are of great value.
Method
We collected 300 cases of clinical CT data of the femur. We introduced the adaptive function adjustment module to the neural network PointNet++ to strengthen the global feature extraction of the point cloud for improving the accuracy of femur segmentation. We used the improved PointNet++ network to segment the femur into three parts: femoral head, femoral neck, and femoral shaft. We evaluated the segmentation accracy using Dice Coefficient, MIoU, recall, and precision indicators. We achieved the automatic measurement of the proximal femoral parameters using the shape fitting algorithms, and compared the automatic and manual measurement results.
Results
The Dice, MIoU, recall and precision indicator of the improved segmentation algorithm reached 98.05%, 96.55%, 96.63%, and 96.03%, respectively. The comparison between automatic and manual measurement results showed that the mean accuracies of all parameters were above 95%, the mean errors were less than 5 mm and 3°, and the ICC values were more than 0.8, indicating that the automatic measurement results were accurate.
Conclusion
Our improved PointNet++ network provided high‐precision segmentation of the femur. We further completed automatic measurement of the femur parameters and verified its high accuracy. This method is of great value for the diagnosis and preoperative planning of hip diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Computer, Xi'an University of Posts and Telecommunications, Xi'an, Shaanxi, China.
- Department of Bone and Joint Surgery, The Second Affiliated Hospital of Medical College, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
- Department of Radiology, The Second Affiliated Hospital of Medical College, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
ORCID-Profile: Jiayu Yang, Pei Yang
Förderung
- Shaanxi Key Laboratory of Network Data Intelligent Processing
Zitieren
APA
Yang, J., Li, Z., Zhan, P., Li, X., Wang, K., Han, J., & Yang, P. (2023). Proximal femur parameter measurement via improved PointNet++. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.2494
Vancouver
Yang J, Li Z, Zhan P, Li X, Wang K, Han J, et al. Proximal femur parameter measurement via improved PointNet++. The International Journal of Medical Robotics and Computer Assisted Surgery. 2023. doi:10.1002/rcs.2494
BibTeX
@article{Yang2023,
author = {Yang, Jiayu and Li, Zhe and Zhan, Pengyu and Li, Xinghua and Wang, Kunzheng and Han, Jungang and Yang, Pei},
title = {Proximal femur parameter measurement via improved PointNet++},
journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
year = {2023},
doi = {10.1002/rcs.2494}
}
EUVIMED