EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of lower limb kinematics and kinetics estimation of basketball players during jumping with markerless and marker-based motion capture systems

Linyu Wei, Changzhi Yang, Xi Huang, Lili Tu, Yanjia Xu, Ming Li, Zhe Hu

Acta of Bioengineering and Biomechanics · 2025

DOI: 10.37190/abb/207092 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Acta of Bioengineering and Biomechanics, 2025. Verfasst von Linyu Wei und 6 weiteren Autor:innen. Beteiligte Einrichtung: 1School of Physical Education, Southwest Medical University, Luzhou, China. Hauptthemen laut MEDLINE: Lower Extremity, Basketball, Motion Capture, Imaging, Three-Dimensional.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study compares lower limb kinematics and kinetics estimated by MB and ML motion capture systems during jumps.

Methods

Methods: Twelve subjects performed the standing vertical jump (SVJ), standing long jump (SLJ) and running vertical jump (RVJ) tests.Data was collected using 10 infrared cameras, 6 high-resolution cameras, and two force platforms via Vicon Nexus software. Markerless motion capture calculates sagittal plane angles, torque and power of the Hip, Knee and Ankle joints via Theia3D software, with these parameters also calculated by the marker-based Vicon system. Both systems' data are then processed in Visual3D. Correlation (r), root mean square difference (RMSD), and maximum/minimum errors were analyzed, along with statistical parametric mapping (SPM).

Results

Results: SLJ capture was slightly inferior in both systems. SPM analysis of the sagittal plane showed significant differences only at the hip joint. Joint angle RMSD was < 8.2°, torque RMSD < 0.41 N·M/kg, and power RMSD < 1.76 W/kg.

Conclusions

Conclusion: The ML system accurately captures knee and ankle joints in the sagittal plane but shows significant differences in hip measurement and certain movements, requiring further validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lower ExtremityBasketballMotion CaptureImaging, Three-DimensionalAthletesHumansBiomechanical PhenomenaReproducibility of ResultsMaleYoung AdultKineticsMovement

Stichwörter der Autor:innen

basketballbiomechanicsjumpingmark-based motion capture systemmarkerless motion capture system

Autor:innen und Institutionen

  • 1School of Physical Education, Southwest Medical University, Luzhou, China.
  • 2Hainan Provincial Key Laboratory of Sports and Health Promotion, Key Laboratory of Emergency and Trauma, Ministry of Education, The First Affiliated Hospital of Hainan Medical University, Hainan Medical University, Hai…
  • 3Shandong Sport University, Jinan ,China.
  • 4Department of Physical Education, Jeonbuk National University, Jeonju, South Korea.
  • 5College of Education and Sports Sciences, Yangtze University, Jingzhou, Hubei, China.

Zitieren

APA

Wei, L., Yang, C., Huang, X., Tu, L., Xu, Y., Li, M., & Hu, Z. (2025). Comparison of lower limb kinematics and kinetics estimation of basketball players during jumping with markerless and marker-based motion capture systems. Acta of Bioengineering and Biomechanics. https://doi.org/10.37190/abb/207092

Vancouver

Wei L, Yang C, Huang X, Tu L, Xu Y, Li M, et al. Comparison of lower limb kinematics and kinetics estimation of basketball players during jumping with markerless and marker-based motion capture systems. Acta of Bioengineering and Biomechanics. 2025. doi:10.37190/abb/207092

BibTeX
@article{Wei2025,
  author = {Wei, Linyu and Yang, Changzhi and Huang, Xi and Tu, Lili and Xu, Yanjia and Li, Ming and Hu, Zhe},
  title = {Comparison of lower limb kinematics and kinetics estimation of basketball players during jumping with markerless and marker-based motion capture systems},
  journal = {Acta of Bioengineering and Biomechanics},
  year = {2025},
  doi = {10.37190/abb/207092}
}
Kostenlos starten →