Accuracy and Validity of 3D Markerless Motion Capture Compared to Marker-Based Systems for Lower-Limb Biomechanical Assessment: A Systematic Review
Sensors · 22.06.2026 · 26 (12) · 3956
DOI: 10.3390/s26123956 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Sensors, online erschienen am 22.06.2026. Verfasst von Aditya Chougule und 6 weiteren Autor:innen. Beteiligte Einrichtung: Trauma and Orthopaedics Department, University of Cambridge, Cambridge CB21TN, UK. Hauptthemen laut MEDLINE: Motion Capture, Lower Extremity, Imaging, Three-Dimensional. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Marker-based motion capture systems are considered the gold standard for biomechanical analysis of movements associated with anterior cruciate ligament (ACL) injury risk; however, their cost and technical requirements limit their use for large-scale athlete screening. Markerless motion capture has emerged as a potential alternative, using pose estimation algorithms or depth cameras to quantify movement without reflective markers. This systematic review evaluated the accuracy and validity of markerless motion capture systems for measuring lower-limb kinematics during jump-landing tasks commonly used in ACL injury screening. MEDLINE, Embase, and Web of Science were searched from 1990 to March 2025 for studies comparing markerless and marker-based systems in healthy participants. Extracted outcomes included Bland-Altman plots, root mean square error, mean absolute error, Pearson’s correlation coefficient, coefficient of multiple correlation, and intraclass correlation coefficient. Across studies, markerless systems demonstrated moderate to high validity for several lower-limb kinematic measures, particularly in the sagittal plane, although validity varied across joints, movement phases, and task complexity. These findings suggest markerless motion capture shows potential for biomechanical assessment in ACL injury screening, but further validation is required before widespread implementation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Trauma and Orthopaedics Department, University of Cambridge, Cambridge CB21TN, UK.
ORCID-Profile: Matthew Dowsett, David Ekundayomi, Ava Machesney, Stephen McDonnell
Zitieren
APA
Chougule, A., Dowsett, M., Ekundayomi, D., Machesney, A., Mather, T., Gompels, B., & McDonnell, S. (2026). Accuracy and Validity of 3D Markerless Motion Capture Compared to Marker-Based Systems for Lower-Limb Biomechanical Assessment: A Systematic Review. Sensors, 26(12), 3956. https://doi.org/10.3390/s26123956
Vancouver
Chougule A, Dowsett M, Ekundayomi D, Machesney A, Mather T, Gompels B, et al. Accuracy and Validity of 3D Markerless Motion Capture Compared to Marker-Based Systems for Lower-Limb Biomechanical Assessment: A Systematic Review. Sensors. 2026;26(12):3956. doi:10.3390/s26123956
BibTeX
@article{Chougule2026,
author = {Chougule, Aditya and Dowsett, Matthew and Ekundayomi, David and Machesney, Ava and Mather, Tomos and Gompels, Benjamin and McDonnell, Stephen},
title = {Accuracy and Validity of 3D Markerless Motion Capture Compared to Marker-Based Systems for Lower-Limb Biomechanical Assessment: A Systematic Review},
journal = {Sensors},
year = {2026},
volume = {26},
number = {12},
pages = {3956},
doi = {10.3390/s26123956}
}
EUVIMED