Feasibility of diamond membrane detector to measure linear energy transfer in multi-ion beam therapy
Japanese Journal of Applied Physics · 30.04.2026 · 65 (8) · 086001
DOI: 10.35848/1347-4065/ae5da4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Japanese Journal of Applied Physics, online erschienen am 04.05.2026. Verfasst von Katsumi Aoki und 6 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
The linear energy transfer (LET) painting technique, which increases the dose-averaged LET (LET d ) value in whole-tumor targets, can improve the probability of tumor control. The LET d calculated by a treatment planning system (TPS) must be verified relative to the measured LET d value; however, standardized methods to measure LET d have not been established. The diamond membrane detector can potentially apply the LET d measurement of beam species used in ion beam radiotherapy. The LET d measurements were performed using a diamond detector for irradiation with three beam species (carbon, oxygen, and neon) at four beam intensities. The measured LET d values agreed with the LET d values calculated by the TPS within the uncertainty. The values were comparable to those measured using a silicon-on-insulator detector, which is currently being utilized in clinical trials for LET-painting carbon-ion radiotherapy. The results indicate that the diamond detector can be applied to quality assurance/QC measurements to verify the LET d .
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Aoki, K., Yonai, S., Takei, H., Matsumoto, T., Makino, T., Matsumoto, S., & Kada, W. (2026). Feasibility of diamond membrane detector to measure linear energy transfer in multi-ion beam therapy. Japanese Journal of Applied Physics, 65(8), 086001. https://doi.org/10.35848/1347-4065/ae5da4
Vancouver
Aoki K, Yonai S, Takei H, Matsumoto T, Makino T, Matsumoto S, et al. Feasibility of diamond membrane detector to measure linear energy transfer in multi-ion beam therapy. Japanese Journal of Applied Physics. 2026;65(8):086001. doi:10.35848/1347-4065/ae5da4
BibTeX
@article{Aoki2026,
author = {Aoki, Katsumi and Yonai, Shunsuke and Takei, Hideyuki and Matsumoto, Takumi and Makino, Takahiro and Matsumoto, Shinnosuke and Kada, Wataru},
title = {Feasibility of diamond membrane detector to measure linear energy transfer in multi-ion beam therapy},
journal = {Japanese Journal of Applied Physics},
year = {2026},
volume = {65},
number = {8},
pages = {086001},
doi = {10.35848/1347-4065/ae5da4}
}
EUVIMED