Oxygen Depletion in FLASH Particle Therapy: Effects of Linear Energy Transfer and Ion Track Structure
Antioxidants · 06.03.2026 · 15 (3) · 331
DOI: 10.3390/antiox15030331 ↗Kurz gefasst
Fachartikel in der Zeitschrift Antioxidants, online erschienen am 06.03.2026. Verfasst von Jintana Meesungnoen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging and Radiation Sciences, Faculty of Medicine and Health Sciences, Université de Sherbrooke, 3001, 12th Avenue Nord, Sher…. Die Arbeit nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Canadian Institutes of Health Research (CIHR), Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Ultra-high dose-rate (FLASH) irradiation can transiently deplete oxygen and modulate radical-mediated chemistry in irradiated cells. Cellular antioxidants also contribute to mitigating oxidative damage in a manner dependent on linear energy transfer (LET), as suggested by recent experimental studies. In this work, we employed our multi-track Monte Carlo simulation framework (IONLYS-IRT) to investigate how LET influences transient radiation-induced oxygen depletion (ROD) in a cell-like aqueous environment under FLASH irradiation conditions. FLASH exposures were modeled as single, instantaneous pulses of protons with energies from 300 MeV to 150 keV, corresponding to LET values of ~0.3 to 71 keV/μm. Our simulations revealed a marked decline in oxygen depletion with increasing LET, in agreement with experimental observations. For an intracellular O2 concentration of 30 μM, the oxygen consumption yield, G(–O2), decreased from ~4.0 molecules/100 eV at low LET (~0.3 keV/μm) to ~1.6 molecules/100 eV at high LET (~71 keV/μm), representing a ~60% reduction. To assess whether ROD depends solely on LET or is also governed by ion track structure, we systematically compared multiple ion species (protons, 4He2+, 10B5+, 12C6+, 16O8+, 20Ne10+, 28Si14+, 32S16+, and 40Ar18+) at comparable LET values. At ~70 keV/μm, heavier ions produced significantly higher G(−O2) values than protons—though still below those at low LET—suggesting that track structure plays a key role beyond LET alone. These findings highlight the dual importance of LET and ion-specific track structure in modulating ROD under FLASH conditions. Notably, enhanced ROD in surrounding normal tissues (low-LET plateau regions) may contribute to radioprotective effects, whereas reduced ROD in tumor tissues (high-LET Bragg peak regions) would be expected to preserve tumoricidal efficacy. Together, these results provide a mechanistic framework for optimizing proton and heavy-ion approaches in FLASH radiotherapy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Imaging and Radiation Sciences, Faculty of Medicine and Health Sciences, Université de Sherbrooke, 3001, 12th Avenue Nord, Sherbrooke, QC J1H 5N4, Canada.
ORCID-Profile: Jean-Paul Jay-Gerin
Förderung
- Canadian Institutes of Health Research (CIHR)
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Meesungnoen, J., & Jay-Gerin, J. P. (2026). Oxygen Depletion in FLASH Particle Therapy: Effects of Linear Energy Transfer and Ion Track Structure. Antioxidants, 15(3), 331. https://doi.org/10.3390/antiox15030331
Vancouver
Meesungnoen J, Jay-Gerin JP. Oxygen Depletion in FLASH Particle Therapy: Effects of Linear Energy Transfer and Ion Track Structure. Antioxidants. 2026;15(3):331. doi:10.3390/antiox15030331
BibTeX
@article{Meesungnoen2026,
author = {Meesungnoen, Jintana and Jay-Gerin, Jean-Paul},
title = {Oxygen Depletion in FLASH Particle Therapy: Effects of Linear Energy Transfer and Ion Track Structure},
journal = {Antioxidants},
year = {2026},
volume = {15},
number = {3},
pages = {331},
doi = {10.3390/antiox15030331}
}
EUVIMED